Offset probe issue
Hi Rich,
This firmware is very promising thanks for sharing, been testing it out I am facing a strange problem, when I auto calibrate, the offset probe tip shows good leveled result over the bed. But when I test nozzle tip the leveling is gone. I have set probe offsets properly, how can I get same good level on nozzle with an offset probe? M666L on my machine shows, thanks for any tip.
X (Endstop Adj): -3.315 Y (Endstop Adj): -0.030 Z (Endstop Adj): -1.195 P (Z-Probe Offset): X-0.70 Y22.40 Z-6.00 A (Tower A Position Correction): 0.000 B (Tower B Position Correction): 0.000 C (Tower C Position Correction): 0.000 I (Tower A Radius Correction): -1.125 J (Tower B Radius Correction): -4.125 K (Tower C Radius Correction): -2.531 U (Tower A Diagional Rod Correction): 0.000 V (Tower B Diagonal Rod Correction): 0.000 W (Tower C Diagonal Rod Correction): 0.000 R (Delta Radius): 114.66 D (Diagonal Rod Length): 217.84 H (Z-Height): 216.13
Im not sure what you mean, but im assuming that you have saved the settngs with M500 after the G30 completes?
Also, it might be that your probe is activating a little higher than you think it is, resulting in the bed level when trying to print being too low across the bed - in this case try reducing the H parameter (with M666 H) by .3 or so and then save with M500 again and try a print and see what happens..
Rich