Offset probe issue

Open aliahsansyed opened this issue 9 years ago • 1 comments

Hi Rich,

This firmware is very promising thanks for sharing, been testing it out I am facing a strange problem, when I auto calibrate, the offset probe tip shows good leveled result over the bed. But when I test nozzle tip the leveling is gone. I have set probe offsets properly, how can I get same good level on nozzle with an offset probe? M666L on my machine shows, thanks for any tip.

X (Endstop Adj): -3.315 Y (Endstop Adj): -0.030 Z (Endstop Adj): -1.195 P (Z-Probe Offset): X-0.70 Y22.40 Z-6.00 A (Tower A Position Correction): 0.000 B (Tower B Position Correction): 0.000 C (Tower C Position Correction): 0.000 I (Tower A Radius Correction): -1.125 J (Tower B Radius Correction): -4.125 K (Tower C Radius Correction): -2.531 U (Tower A Diagional Rod Correction): 0.000 V (Tower B Diagonal Rod Correction): 0.000 W (Tower C Diagonal Rod Correction): 0.000 R (Delta Radius): 114.66 D (Diagonal Rod Length): 217.84 H (Z-Height): 216.13

aliahsansyed avatar May 11 '15 05:05 aliahsansyed

Im not sure what you mean, but im assuming that you have saved the settngs with M500 after the G30 completes?

Also, it might be that your probe is activating a little higher than you think it is, resulting in the bed level when trying to print being too low across the bed - in this case try reducing the H parameter (with M666 H) by .3 or so and then save with M500 again and try a print and see what happens..

Rich