2.10.1 shows wrong temperatur

Open skoehler opened this issue 4 years ago • 27 comments

I just updated by TS100 to version 2.10.1. Now, after powering on, the temperature shown is 520°C. The tip is cold! When powering on after the update, all settings were reset. I also tried a manual reset.

I was running the Ralim firmware before and the soldering iron was working just fine yesterday. But I don't know which version I was using before.

skoehler avatar Jun 24 '20 09:06 skoehler

I'm using the TS-C1 tip

skoehler avatar Jun 24 '20 09:06 skoehler

v2.05.01 works

skoehler avatar Jun 24 '20 09:06 skoehler

Uhhhh.... That is very weird I have to say.

Almost feels like your iron has slower timings than normal. Out of curiosity could you use the debug menu and tell me what the tip raw measurement says in that menu with tip in and tip removed when on the new firmware ?

Ralim avatar Jun 24 '20 10:06 Ralim

My TS100 is from April 2018, bought it via Banggood. I will supply you with the values from the debug menu.

skoehler avatar Jun 24 '20 12:06 skoehler

no DC power, only USB power, tips were at room temperature

TS100 firmware v2.05.1
debug menu shows:
  v2.05 PCB2
  TS-C1: Rtip=1193 Ctip=10
  TS-BC2: Rtip=1182 Ctip=8
  no tip: Rtip=16379 Ctip=470

TS100 firmware v2.10.1
debug menu shows:
  v2.10 git
  PCB2
  TS-C1: Rtip=830 Ctip=6528
  TS-BC2: Rtip=700 Ctip=6529
  no tip: Rtip=10407 Ctip=6980

skoehler avatar Jun 24 '20 12:06 skoehler

Does the provided information tell you anything?

skoehler avatar Jun 24 '20 15:06 skoehler

A fair bit of head scratching in confusion :confused: . Ill look at it a bit tonight :)

Ralim avatar Jun 25 '20 03:06 Ralim

Ctip = (Rtip - TipOffset) / TipGain May be TipOffset is negative somehow?

Firebie avatar Jun 25 '20 11:06 Firebie

@skoehler

Apologies for this getting lost. Is this still occuring for you with latest firmwares?

Ralim avatar Sep 14 '20 12:09 Ralim

Version 2.12 still shows 520 °C when the tip is cold.

skoehler avatar Sep 14 '20 23:09 skoehler

It should only show that when the tip is disconnected :/

Have not been able to reproduce this at all across an entirely new set of tips..

Out of curiosity if you run the calibration when cold what number does it show you ?

Ralim avatar Sep 14 '20 23:09 Ralim

I will try the calibration. But it seems that my Ctip and Rtip values are completely bogus, even when no tip is connected. See my post above. Do you think calibration will help?

skoehler avatar Sep 15 '20 01:09 skoehler

Your rtip values are reading lower then normal, which most likely means that your iron does not use the exact same op-amp part as other irons, but with calibration should be in range as that should derive a lower calibration number for you that should compensate i believe.

Ralim avatar Sep 15 '20 01:09 Ralim

I tried v2.12-beta, but the calibration changes nothing! The iron shows four dots and then shows 781 next to some box. Seems like that is the new calibration value. Then, after existing the menu, the iron still shows >500°C. I'm confused.

skoehler avatar Sep 17 '20 00:09 skoehler

The calibration of 781 make sense, that is close to your offset. If you power cycle after the calibration is it still showing >500C when the tip is connected?

Ralim avatar Sep 17 '20 00:09 Ralim

Yes, even after a power cycle, the TS100 still shows >500°C. The TS-BC2 tip was connected the whole time.

skoehler avatar Sep 17 '20 01:09 skoehler

Hello, I think I am having a similar issue. I happily used your firmware for a day however while I was using the soldering iron today, it started to not heat up and showing 498°C. While I was trying it to get it to work, it did some spikes where it actually got hot enough to melt the solder. But these spikes only happen for few seconds then it drops its temperature. Would appreciate it if you can give me some ideas. After I calibrated it, It heated to 490+°C again where it was able to melt the solder then droped its heat while still displaying 490+°C for the tips temperature.

tttunci avatar Sep 17 '20 22:09 tttunci

As you can see, a downgrade to v2.05.1 fixes it for me. Have you tried that?

skoehler avatar Sep 17 '20 23:09 skoehler

I just tried it and it gives me the BAD tip error. I just assume my tip somehow got damaged. Thank you for your quick response.

tttunci avatar Sep 17 '20 23:09 tttunci

I have ts100 pcb version V2.5B. ~~here is R1 value 850k, unlike version 2.5A where the value is R1 750k. Do you think this should affect the temperature reading? (R1 reading - my fault eia96 reading see bellow~~ My temperature was shifted a lot. set - measured on FG100 (tip gain default, tip BC2 and B2) 330 - 300 300 - 266 250 - 225 200 - 182 If I set tip gain to 24 it seems to be correct. (version 2.11 used)

dodox1 avatar Jan 01 '21 10:01 dodox1

Ah heck,

Absolutely that will completely change the response of the unit. This is going to be a mess if they have changed a value again without warning.

Where did you buy yours from ?

Ralim avatar Jan 01 '21 10:01 Ralim

OMG, sorry it is EIA-96 marking :see_no_evil: so the R1 value is the same 85D = 750k (It was from aliexpress in 2019, but seems to be original package)

dodox1 avatar Jan 01 '21 10:01 dodox1

Did you try latest 2.13? It uses lookup table instead of linear convertion for tip temp

Firebie avatar Jan 01 '21 11:01 Firebie

TS100 V2.13 test with tip BC2 (room temp calibrated) set - measured 200 - 197 220 - 218 240 - 238 250 - 248 280 - 279 300 - 300 320 - 322 ( I'll make test with B2 )

dodox1 avatar Jan 02 '21 22:01 dodox1

@dodox1 those are fairly close. The system has about 1.5-2% max achievable accuracy without much more calibration that is really not worthwhile.

Ralim avatar Jan 03 '21 00:01 Ralim

@skoehler Do you still experience this issue? Please close this otherwise. 😊

thanks

discip avatar Apr 23 '22 15:04 discip

I will test and inform you.

skoehler avatar Apr 24 '22 10:04 skoehler