Rotating codes not stored in backup
Expected Behavior
When learning the codes of a remote with rotating codes (e.g. SilverCrest / SD_GT) they should be backed up when doing a backup of FHEM.
Actual Behavior
When doing a backup and restoring it, the codes seem to be missing. I have to re-learn the codes of all SD_GT plugs.
Steps to Reproduce the Problem
- Add a SD_GT plug and learn all codes
- Do a FHEM backup
- Restore the backup
Not sure if I'm simply missing a file thats not backed up, otherwise the remotes work great, thanks for this module!
Specifications
- Microcontroller: SIGNALDuino
- Version (Firmware): 3.5.0
- Versionmodul (FHEM Module): 3.5.5
Hast du die Datei fhem.save aus dem Log-Verzeichnis auch wiederhergestellt? Dort sollten die Codes eigentlich mit gespeichert werden, wie z.B. hier:
setstate SD_GT_8070A_A off
setstate SD_GT_8070A_A 2022-12-31 16:58:05 CodesOff 8E3F20,81E490,86BB10
setstate SD_GT_8070A_A 2022-12-31 16:59:58 CodesOn 8FF840,8DDAB0,89A130,851970
setstate SD_GT_8070A_A 2022-12-30 20:54:17 IODev sduinoUSB0
setstate SD_GT_8070A_A 2022-12-31 16:59:58 SendCode 8FF840
setstate SD_GT_8070A_A 2022-12-31 16:59:58 SystemCode 8070A
setstate SD_GT_8070A_A 2022-12-31 16:59:58 SystemCodeDec 526090
setstate SD_GT_8070A_A 2022-12-31 16:59:58 Version 2
setstate SD_GT_8070A_A 2022-12-31 17:21:36 state off
Interessant, das ist genau die Info die ich gesucht habe. Im log Verzeichnis hätte ich allerdings zuletzt gesucht 😵💫 Wie es scheint existiert die Datei in älteren backups aber sie ist nicht benutzt worden nach dem restore, wiederhergestellt hatte ich das ganze backup, ja.
Ich hatte das Backup auf denselben Raspberry aber mit einem frisch installierten Raspbian wiederhergestellt, kann es was damit zu tun haben?
Das kann ich nicht beantworten. Vielleicht fragst du das besser die Experten im Forum von FHEM.