Hello, thanks for all the great work on the breakout board and the accompanying code.
I'm attempting to up the sample rate to 38400 SPS.
To do this I have changed the values written to the MODE1 and MODE2 registers as follows:
ads1262_Reg_Write(MODE1, 0x60); delay(10); ads1262_Reg_Write(MODE2, 0x0F);
When I run the code with these values I observe rail to rail random variation in the output in the signal even when measuring a constant voltage. This is not the expected operation.
Am I missing some other register value that I need to change to get this to work?
Hello James! Did u setup your INPMUX registers instead of just setting up the MODES? e.g. :
PC_ADS1262.ads1262_Reg_Write(INPMUX, B00001010); // ain0 - aincom PC_ADS1262.ads1262_Reg_Write(MODE1, B01100000); PC_ADS1262.ads1262_Reg_Write(MODE2, B01010000);
And regarding the Voltage supply of the ADC are u using +- 2.5V or +5V? I am asking because this will interfere depending on the measurement mode you are using ( PGA enabled or disabled, and the negative measure reference as well). I suggest that you take a look at page 119 of the ads1262 datasheet for more info on that matter.
Edit: Your registers are correct if your electrical connections are following the datasheet guidelines. Edit 2 because I forgot to mention in edit 1: the MODE2 binary I used as example isn't correlated to yours, it is simply an example of my code.
Best regards. Heitor S. Mendes