parameters for viral genomes

Open YiJessePi opened this issue 3 years ago • 3 comments

I was wondering if anyone had the opportunity to test parameters for computing ANI between viral genomes. I guess that the defaults of fragment length of 3000 and minimal number of fragments of 50 is too conservative for small genomes.

YiJessePi avatar Feb 03 '22 19:02 YiJessePi

I too have this question. When i tried running 2 exact same viral contig fna files, the output is none, indicating an ANI<80%, which obviously is incorrect.

boweny920 avatar Mar 29 '22 20:03 boweny920

It might be because you have less fragments than the minimal number of fragments cutoff. The latest version of fastANI use minimal fraction of fragments instead (and I also recommend to reduce the fragments length a bit)

YiJessePi avatar Mar 29 '22 21:03 YiJessePi

It might be because you have less fragments than the minimal number of fragments cutoff. The latest version of fastANI use minimal fraction of fragments instead (and I also recommend to reduce the fragments length a bit)

This worked for me! Thanks much!