Zwave2Mqtt icon indicating copy to clipboard operation
Zwave2Mqtt copied to clipboard

[bug] Adding Fibaro FGSS101 Smoke Sensor crashes Container (still)

Open wzbfyb opened this issue 4 years ago • 1 comments

Version

Build/Run method

  • [x ] Docker
  • [ ] PKG
  • [ ] Manually built (git clone - npm install - npm run build )

Zwave2Mqtt version: 3.3.0

Describe the bug Adding Fibaro Smoke Sensor crashes container, results in dead nodes added

To Reproduce Steps to reproduce the behavior:

  1. Go to 'Settings'
  2. Click on 'Add Node'
  3. tripple klick the B button on the device
  4. See error

Expected behavior Sensor is added

z2m:Zwave Success zwave api call startInclusion +25s
z2m:Zwave controller command { nodeid: 0, state: 1, errcode: 0, help: 'AddDevice Starting' } +3ms
z2m:Zwave controller command { nodeid: 0, state: 4, errcode: 0, help: 'AddDevice Waiting' } +3ms
z2m:Zwave controller command { nodeid: 0, state: 6, errcode: 0, help: 'AddDevice InProgress' } +12s
z2m:Zwave controller command { nodeid: 9, state: 6, errcode: 0, help: 'AddDevice InProgress' } +4ms
z2m:Zwave controller command { nodeid: 9, state: 6, errcode: 0, help: 'AddDevice InProgress' } +437ms
z2m:Zwave Node added 9 +62ms
z2m:Zwave controller command { nodeid: 9, state: 7, errcode: 0, help: 'AddDevice Completed' } +4ms
z2m:Zwave Notification from node 9: Notification - NoOperation (2) +30ms
2020-06-17 10:51:38.692 Warning, Node009, CommandClass Version is 0, Removing CommandClass COMMAND_CLASS_NOTIFICATION
z2m:Zwave ValueAdded: 9-112-1-1 Smoke alarm cancellation delay +245ms
z2m:Zwave ValueAdded: 9-112-1-2 LED indicator and acoustic alarm turned ON / OFF at any alarm type +9ms
z2m:Zwave ValueAdded: 9-112-1-5 Type of alarm frame for association group 1 +9ms
z2m:Zwave ValueAdded: 9-112-1-7 Forced Level of Dimming group 1 +11ms
z2m:Zwave ValueAdded: 9-112-1-10 Temperature report interval +5ms
z2m:Zwave ValueAdded: 9-112-1-12 Temperature report hysteresis +4ms
z2m:Zwave ValueAdded: 9-112-1-13 Alarm broadcast +5ms
z2m:Zwave ValueAdded: 9-112-1-73 Temperature measurement compensation +4ms
z2m:Zwave ValueAdded: 9-112-1-80 Z-Wave range test interval +5ms
2020-06-17 10:51:38.880 Warning, Node009, CommandClass Version is 0, Removing CommandClass COMMAND_CLASS_NOTIFICATION
z2m:Zwave ValueAdded: 9-112-1-81 Temperature alarm threshold +4ms
z2m:Zwave ValueAdded: 9-112-1-82 Smoke Sensor sensitivity +6ms
z2m:Zwave ValueAdded: 9-112-1-83 Black Box sensitivity level +4ms
z2m:Zwave ValueAdded: 9-112-1-84 Malfunction alarm +5ms
z2m:Zwave ValueAdded: 9-112-1-85 Temperature alarm +4ms
z2m:Zwave ValueAdded: 9-112-1-86 Lack of the Z-Wave range alarm +4ms
z2m:Zwave ValueAdded: 9-112-1-87 Low battery alarm +5ms
z2m:Zwave ValueAdded: 9-112-1-88 Consider temperature measurement compensation +4ms
z2m:Zwave ValueAdded: 9-112-1-89 Tamper alarm +5ms
z2m:Zwave node 9 AVAILABLE: FIBARO System - FGSS101 Smoke Sensor (Routing Alarm Sensor) +5ms
2020-06-17 10:51:38.924 Warning, Node009, Node::GetValue - Couldn't find ValueID in Store: HomeID: 0xef52197f, ValueID: (Id 0x02020000099c4013, NodeID 9, Genre config, CC 0x71, Instance 1, Index 514, Type int)
2020-06-17 10:51:38.928 Warning, Exception: Manager.cpp:1570 - 101 - Invalid ValueID passed to GetValueLabel
2020-06-17 10:51:38.931 Warning, Node009, Node::GetValue - Couldn't find ValueID in Store: HomeID: 0xef52197f, ValueID: (Id 0x02020000099c4013, NodeID 9, Genre config, CC 0x71, Instance 1, Index 514, Type int)
2020-06-17 10:51:38.931 Warning, Exception: Manager.cpp:1626 - 101 - Invalid ValueID passed to GetValueUnits
2020-06-17 10:51:38.932 Warning, Node009, Node::GetValue - Couldn't find ValueID in Store: HomeID: 0xef52197f, ValueID: (Id 0x02020000099c4013, NodeID 9, Genre config, CC 0x71, Instance 1, Index 514, Type int)
2020-06-17 10:51:38.932 Warning, Exception: Manager.cpp:1686 - 101 - Invalid ValueID passed to GetValueHelp
2020-06-17 10:51:38.933 Warning, Node009, Node::GetValue - Couldn't find ValueID in Store: HomeID: 0xef52197f, ValueID: (Id 0x02020000099c4013, NodeID 9, Genre config, CC 0x71, Instance 1, Index 514, Type int)
2020-06-17 10:51:38.933 Warning, Exception: Manager.cpp:1789 - 101 - Invalid ValueID passed to IsValueReadOnly
2020-06-17 10:51:38.933 Warning, Node009, Node::GetValue - Couldn't find ValueID in Store: HomeID: 0xef52197f, ValueID: (Id 0x02020000099c4013, NodeID 9, Genre config, CC 0x71, Instance 1, Index 514, Type int)
2020-06-17 10:51:38.933 Warning, Exception: Manager.cpp:1813 - 101 - Invalid ValueID passed to IsValueWriteOnly
2020-06-17 10:51:38.934 Warning, Node009, Node::GetValue - Couldn't find ValueID in Store: HomeID: 0xef52197f, ValueID: (Id 0x02020000099c4013, NodeID 9, Genre config, CC 0x71, Instance 1, Index 514, Type int)
2020-06-17 10:51:38.934 Warning, Exception: Manager.cpp:1741 - 101 - Invalid ValueID passed to GetValueMin
2020-06-17 10:51:38.934 Warning, Node009, Node::GetValue - Couldn't find ValueID in Store: HomeID: 0xef52197f, ValueID: (Id 0x02020000099c4013, NodeID 9, Genre config, CC 0x71, Instance 1, Index 514, Type int)
2020-06-17 10:51:38.934 Warning, Exception: Manager.cpp:1765 - 101 - Invalid ValueID passed to GetValueMax
2020-06-17 10:51:38.934 Warning, Node009, Node::GetValue - Couldn't find ValueID in Store: HomeID: 0xef52197f, ValueID: (Id 0x02020000099c4013, NodeID 9, Genre config, CC 0x71, Instance 1, Index 514, Type int)
2020-06-17 10:51:38.934 Warning, Exception: Manager.cpp:1861 - 101 - Invalid ValueID passed to IsValuePolled
2020-06-17 10:51:38.935 Warning, Node009, Node::GetValue - Couldn't find ValueID in Store: HomeID: 0xef52197f, ValueID: (Id 0x02020000099c4013, NodeID 9, Genre config, CC 0x71, Instance 1, Index 514, Type int)
2020-06-17 10:51:38.935 Warning, Exception: Manager.cpp:2071 - 101 - Invalid ValueID passed to GetValueAsInt
undefined:0

[Error: Exception calling OpenZWave::Manager::GetValueAsInt in /openzwave/cpp/src/Manager.cpp(2071): Invalid ValueID passed to GetValueAsInt]

wzbfyb avatar Jun 18 '20 11:06 wzbfyb

exception should be handled by ozw shared 1.5.7, I need to understand why this still happens...

robertsLando avatar Jun 18 '20 14:06 robertsLando