Gate icon indicating copy to clipboard operation
Gate copied to clipboard

Add phantoms into voxelized phantoms and calculate dose distributions

Open tyxiong123 opened this issue 2 years ago • 2 comments

Hi, I try to calculate dose distributions for seed implant brachytherapy. I firstly imported CT files to construct a voxelized patient phantom using regionalized parameterization method. And then a few I-125 seed models were placed into the voxelized patient phantom. I used DoseActor which was attached to the voxelized patient phantom to record dose distributions. However, results showed that seed models did not influence dose distributions. Is there any way of implanting phantoms into voxelized phantoms and recording correct dose distributions?

tyxiong123 avatar Sep 29 '22 09:09 tyxiong123

Hi, please have a look at https://github.com/OpenGATE/GateBenchmarks/tree/master/t22_merged_actor it may help @JulienBert

dsarrut avatar Sep 29 '22 18:09 dsarrut

Thanks for your help! I tried and it worked.

tyxiong123 avatar Oct 01 '22 05:10 tyxiong123

great ;) !

dsarrut avatar Oct 06 '22 06:10 dsarrut