minor issue (probably only reporting)
I am running some test cases for CO2STORE and I see some weird messages in the PRT file e.g.:
Flo says some keyword are not supported. I suppose it is simply a matter of reporting a wrong piece of information.
Could you confirm this?ù
Regards,
A:
BTW, I am using 2024.10
The CO2STORE implementation in OPM Flow is based on the blackoil simulator. The unsupported keywords in the list are compositional keyword, they are not needed and will be ignored. To setup a basic CO2STORE run you will need to use
CO2STORE GAS WATER DISGASW (optional, if you would like to model dissolution of CO2 in brine) VAPWAT (optional, if you would like to model vaporization of water) THERMAL (optional) DIFFUSE (optional) in the RUNSPEC section.
You will also need to set the salinity using the SALINITY keyword in the PROPS section. (i.e. you don't specify the salt components using COMPS)
The unsupported keywords in the list are compositional keyword, they are not needed and will be ignored.
Right, but this appears to be CO2STORE_GASWAT from OPM-Tests and that model uses those COMPS, GASWAT &c compositional keywords. It's not really ideal if our own examples use misleading setup.