opm-simulators icon indicating copy to clipboard operation
opm-simulators copied to clipboard

Model 1 From SPE 10 Benchmark No Longer Produces Expected Output

Open bska opened this issue 1 year ago • 2 comments

I tested the SPE10_MODEL1.DATA from the OPM-Data repository this morning and the model no longer produces the expected output from Flow (mpirun -np 8 ${cse}). The injector shuts down immediately and then there's no dynamic change to the model state after that. For what it's worth, this model ran perfectly two weeks ago (28th August).

I consider this to be a release blocker for the 2024.10 release.

bska avatar Sep 09 '24 07:09 bska

As I said to Bård, this case is not running with flow and flow_blackoil, while surprisingly running with flow_blackoil_alugrid when enabling sfc ordering!

ElyesAhmed avatar Sep 09 '24 11:09 ElyesAhmed

not so urgent but WELTRAJ case in opm-tests is also not running

ElyesAhmed avatar Sep 18 '24 11:09 ElyesAhmed