Laird module different xtal config

Open Colin-at-511100471793 opened this issue 4 years ago • 0 comments

Hi there... if you're having trouble with a laird module devkit not being able to run this example...

you need to attach the external 32khz clock which is not attached by default.. the crystal is there but there's 2 solder bridges that need to be connected and 2 0402 resistors that need to be removed in order for the clock to lock.. you'll see it right next to the module on the devkit...

This is really a problem with Laird's documentation- not Nordics... but laird directs you here.. so I thought I'd post this here... It'd be nice if you could leave this issue/solution up for future lost soles ;)

Colin-at-511100471793 avatar Oct 28 '20 14:10 Colin-at-511100471793