BSOD when FSUIPC is closed while MF Connector is running
Describe the bug Windows shows blue screen with error UNEXPECTED_KERNEL_MODE_TRAP when FSUIPC stops running while MF Connector is running. There is an infinite loop of messages that FSUIPC has disconnected, then the computer crashes.
Steps To Reproduce Steps to reproduce the behavior:
- Have MF Connector with FSUIPC7 running.
- Close FSUIPC7
Expected behavior Error message shows and MF Connector stops running.
Actual behavior MF Connector opens infinitely many notification windows that FSUIPC is disconnected, then the computer crashes.
Details
- MobiFlight Version: 9.4.0
- FlightSim: MSFS2020
- FSUIPC7 Version: 7.3.7
Can not reproduce. MF 9.4.0.4 BETA FS2020 1.26.5.0 FSUIPC 7.2.16
@DaGinYus - Can you still reproduce this with the 9.5 version and a newer FSUIPC?
The issue seems to have been resolved