MAD-X icon indicating copy to clipboard operation
MAD-X copied to clipboard

synchrotron radiation integrals zero with zero length elements

Open skostogl opened this issue 3 years ago • 1 comments

Synchrotron radiation integrals ("synch_*") are computed correctly with thick elements but are set to 0 when a thin sequence is used. Probably related to LRAD.

skostogl avatar Jan 21 '22 15:01 skostogl