### Is your feature request related to a problem? Please describe Many new Philips hue devices support gradients (I'm counting at least 23 in `philips.js`, out of which 6 of...

feature request

### Is your feature request related to a problem? Please describe [Adurosmart eria](https://www.zigbee2mqtt.io/devices/15090054.html) is missing long press button support. ### Describe the solution you'd like To have support for long...

feature request

### What happened? My Eurotronic Spirit SPBZ0001 Thermostat sends manual changes on the temperature only as current_heating_setpoint. So Homeassistant and Zigbee2Mqtt don't Show the actual setpoint. It uses firmware 20190408....

problem

### What happened? I use Conbee2 USB stick in my Home Assistant test instance: - HA OS 9.3 (the same with 9.2) - HA Core 2022.10.5 (the same with 2022.9.7)...

problem
stale

### What happened? Very frequent error Template variable warning: 'dict object' has no attribute 'motor_state' when rendering '{{ value_json.motor_state }}'. I thought I had resolved it in https://github.com/Koenkk/zigbee2mqtt/issues/14023, but that's...

problem

### Is your feature request related to a problem? Please describe When have dozens of devices with original IEEE name, it is difficult to understand where are you at the...

feature request

### Link https://www.se.com/ww/en/product/SDD111389/connected-wireless-switch-1gang-2gang-white/ ### Database entry {"id":4,"type":"EndDevice","ieeeAddr":"0x04cd15fffeb91e0a","nwkAddr":30030,"manufId":4190,"manufName":"Schneider Electric","powerSource":"Battery","modelId":"FLS/SYSTEM-M/4","epList":[21,22,23,24],"endpoints":{"21":{"profId":260,"epId":21,"devId":260,"inClusterList":[0,1,3,32,65303],"outClusterList":[3,4,5,6,8,25,258],"clusters":{"genBasic":{"attributes":{"modelId":"FLS/SYSTEM-M/4","manufacturerName":"Schneider Electric","powerSource":3,"zclVersion":3,"appVersion":2,"stackVersion":6,"hwVersion":1,"dateCode":"","swBuildId":"002.009.001 R"}},"genPollCtrl":{"attributes":{"checkinInterval":86400}},"genPowerCfg":{"attributes":{"batteryPercentageRemaining":160}}},"binds":[{"cluster":32,"type":"endpoint","deviceIeeeAddress":"0x00124b00259068c1","endpointID":1},{"cluster":6,"type":"endpoint","deviceIeeeAddress":"0x00124b00259068c1","endpointID":1},{"cluster":8,"type":"endpoint","deviceIeeeAddress":"0x00124b00259068c1","endpointID":1},{"cluster":1,"type":"endpoint","deviceIeeeAddress":"0x00124b00259068c1","endpointID":1}],"configuredReportings":[{"cluster":1,"attrId":33,"minRepIntval":3600,"maxRepIntval":62000,"repChange":0}],"meta":{}},"22":{"profId":260,"epId":22,"devId":260,"inClusterList":[0,1,3,65303],"outClusterList":[3,4,5,6,8,258],"clusters":{"genBasic":{"attributes":{"dateCode":""}}},"binds":[{"cluster":6,"type":"endpoint","deviceIeeeAddress":"0x00124b00259068c1","endpointID":1},{"cluster":8,"type":"endpoint","deviceIeeeAddress":"0x00124b00259068c1","endpointID":1}],"configuredReportings":[],"meta":{}},"23":{"profId":260,"epId":23,"devId":260,"inClusterList":[0,1,3,65303],"outClusterList":[3,4,5,6,8,258],"clusters":{"genBasic":{"attributes":{"dateCode":""}}},"binds":[],"configuredReportings":[],"meta":{}},"24":{"profId":260,"epId":24,"devId":260,"inClusterList":[0,1,3,65303],"outClusterList":[3,4,5,6,8,258],"clusters":{"genBasic":{"attributes":{"dateCode":""}}},"binds":[],"configuredReportings":[],"meta":{}}},"appVersion":2,"stackVersion":6,"hwVersion":1,"dateCode":"","swBuildId":"002.009.001 R","zclVersion":3,"interviewCompleted":true,"meta":{"configured":-717026909},"lastSeen":1669719022765,"defaultSendRequestWhen":"active"} ### Comments This device gets identified as a 1-gang switch and works as such out of the box as...

new device support

### What happened? I have set the programming mode, that means between some defined hours I have X temperature (for example 21), in other time intervals, different temperatures. When for...

problem

### What happened? After a "while" of no use, the 5-button remote from IKEA have to be re-paired to work. It has not gone missing from the list of devices...

problem

### Link https://nl.aliexpress.com/item/1005004838346776.html?spm=a2g0o.order_list.0.0.21ef79d23TQkYy&gatewayAdapt=glo2nld ### Database entry {"id":2,"type":"EndDevice","ieeeAddr":"0xa4c13802b5d7be5f","nwkAddr":23500,"manufId":4417,"manufName":"_TZE200_yjjdcqsq","powerSource":"Battery","modelId":"TS0601","epList":[1],"endpoints":{"1":{"profId":260,"epId":1,"inClusterList":[4,5,61184,0],"outClusterList":[25,10],"clusters":{"genBasic":{"attributes":{"65503":"�\u0019�*\u0019�\u0019�*\u0007\u0000\u0000\u0000\u0000\u0011","65506":56,"65508":1,"stackVersion":0,"dateCode":"","appVersion":72}}},"binds":[{"cluster":0,"type":"endpoint","deviceIeeeAddress":"0xe0798dfffe77ff5d","endpointID":1}],"configuredReportings":[],"meta":{}}},"appVersion":72,"stackVersion":0,"hwVersion":1,"dateCode":"","zclVersion":3,"interviewCompleted":true,"meta":{"configured":821693351},"lastSeen":1667649633218,"defaultSendRequestWhen":"immediate"} ### Comments I have tried a few things, looked for (very) similar devices in the tuya.js file, and tried a few things but...