zigbee2mqtt
zigbee2mqtt copied to clipboard
[New device support]: 3 Phase Electricity Meter Unsupported device model 'TS0601' and manufacturer name '_TZE200_ywbltqzw'
Link
https://www.aliexpress.com/item/1005004883393092.html
Database entry
{"id":21,"type":"Router","ieeeAddr":"0xa4c138d5be107401","nwkAddr":27327,"manufId":4417,"manufName":"_TZE200_ywbltqzw","powerSource":"Mains (single phase)","modelId":"TS0601","epList":[1,242],"endpoints":{"1":{"profId":260,"epId":1,"devId":81,"inClusterList":[4,5,61184,0],"outClusterList":[25,10],"clusters":{"genBasic":{"attributes":{"65503":"��\u0014+i��\u0014+i��\u0014+i��\u0014+i��\u0014+i��\u0014+i��\u0014+i��\u0014+i��\u0014+i��\u0014+i","65506":48,"65508":0,"modelId":"TS0601","manufacturerName":"_TZE200_ywbltqzw","powerSource":1,"zclVersion":3,"appVersion":68,"stackVersion":0,"hwVersion":1,"dateCode":""}}},"binds":[],"configuredReportings":[],"meta":{}},"242":{"profId":41440,"epId":242,"devId":97,"inClusterList":[],"outClusterList":[33],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}}},"appVersion":68,"stackVersion":0,"hwVersion":1,"dateCode":"","zclVersion":3,"interviewCompleted":true,"meta":{},"lastSeen":1669465017123,"defaultSendRequestWhen":"immediate"}
Comments
The device does not show any parameters and they cannot be controlled
I tried to create a converter but it came to nothing...
For example XOCA DAC2161C (MatSee Plus)
External converter
const fz = require('zigbee-herdsman-converters/converters/fromZigbee');
const tz = require('zigbee-herdsman-converters/converters/toZigbee');
const exposes = require('zigbee-herdsman-converters/lib/exposes');
const reporting = require('zigbee-herdsman-converters/lib/reporting');
const extend = require('zigbee-herdsman-converters/lib/extend');
const e = exposes.presets;
const ea = exposes.access;
const tuya = require('zigbee-herdsman-converters/lib/tuya');
const definition = {
// Since a lot of TuYa devices use the same modelID, but use different datapoints
// it's necessary to provide a fingerprint instead of a zigbeeModel
fingerprint: [
{
// The model ID from: Device with modelID 'TS0601' is not supported
// You may need to add \u0000 at the end of the name in some cases
modelID: 'TS0601',
// The manufacturer name from: Device with modelID 'TS0601' is not supported.
manufacturerName: '_TZE200_ywbltqzw',
},
],
model: 'PJ-DAC7361C',
vendor: 'TuYa',
description: 'Zigbee DIN 3-phase energy meter',
fromZigbee: [tuya.fz.datapoints],
toZigbee: [tuya.tz.datapoints],
whiteLabel: [{vendor: 'XOCA', model: 'DAC7361C'}],
//onEvent: tuya.onEventSetTime, // Add this if you are getting no converter for 'commandMcuSyncTime'
configure: tuya.configureMagicPacket,
exposes: [
e.voltage(), e.current(), e.power(), e.energy(),
tuya.exposes.switch(),
tuya.exposes.energyWithPhase('a'), tuya.exposes.energyWithPhase('b'), tuya.exposes.energyWithPhase('c'),
tuya.exposes.voltageWithPhase('a'), tuya.exposes.voltageWithPhase('b'), tuya.exposes.voltageWithPhase('c'),
tuya.exposes.powerWithPhase('a'), tuya.exposes.powerWithPhase('b'), tuya.exposes.powerWithPhase('c'),
tuya.exposes.currentWithPhase('a'), tuya.exposes.currentWithPhase('b'), tuya.exposes.currentWithPhase('c'),
tuya.exposes.powerFactorWithPhase('a'), tuya.exposes.powerFactorWithPhase('b'), tuya.exposes.powerFactorWithPhase('c'),
exposes.enum('fault', ea.STATE, ['clear', 'over_current_threshold', 'over_power_threshold',
'over_voltage threshold', 'wrong_frequency_threshold']).withDescription('Fault status of the device (clear = nothing)'),
exposes.enum('threshold_1', ea.STATE, ['not_set', 'over_current_threshold', 'over_voltage_threshold'])
.withDescription('State of threshold_1'),
exposes.binary('threshold_1_protection', ea.STATE, 'ON', 'OFF')
.withDescription('OFF - alarm only, ON - relay will be off when threshold reached'),
exposes.numeric('threshold_1_value', ea.STATE)
.withDescription('Can be in Volt or Ampere depending on threshold setting. Setup the value on the device'),
exposes.enum('threshold_2', ea.STATE, ['not_set', 'over_current_threshold', 'over_voltage_threshold'])
.withDescription('State of threshold_2'),
exposes.binary('threshold_2_protection', ea.STATE, 'ON', 'OFF')
.withDescription('OFF - alarm only, ON - relay will be off when threshold reached'),
exposes.numeric('threshold_2_value', ea.STATE)
.withDescription('Setup value on the device'),
exposes.binary('clear_fault', ea.STATE_SET, 'ON', 'OFF')
.withDescription('Turn ON to clear last the fault'),
exposes.text('meter_id', ea.STATE).withDescription('Meter ID (ID of device)'),
],
meta: {
// All datapoints go in here
tuyaDatapoints: [
[1, 'energy', tuya.valueConverter.divideBy100],
[3, null, null], // Monthly, but sends data only after request
[4, null, null], // Dayly, but sends data only after request
[6, null, tuya.valueConverter.phaseVariant2WithPhase('a')],
[7, null, tuya.valueConverter.phaseVariant2WithPhase('b')],
[8, null, tuya.valueConverter.phaseVariant2WithPhase('c')],
[9, 'power', tuya.valueConverter.raw],
[10, 'fault', tuya.valueConverterBasic.lookup({'clear': 0, 'over_current_threshold': 1,
'over_power_threshold': 2, 'over_voltage_threshold': 4, 'wrong_frequency_threshold': 8})],
[11, null, null], // Frozen - strange function, in native app - nothing is clear
[16, 'state', tuya.valueConverter.onOff],
[17, null, tuya.valueConverter.threshold], // It's settable, but can't write converter
[18, 'meter_id', tuya.valueConverter.raw],
[20, 'clear_fault', tuya.valueConverter.onOff], // Clear fault
[21, null, null], // Forward Energy T1 - don't know what this
[22, null, null], // Forward Energy T2 - don't know what this
[23, null, null], // Forward Energy T3 - don't know what this
[24, null, null], // Forward Energy T4 - don't know what this
],
},
};
module.exports = definition;
Supported color modes
No response
Color temperature range
No response
Almost the same hardware here: Zigbee Model: TS0601 Zigbee Manufacturer: _TZE204_x8fp01wi
This issue is stale because it has been open 30 days with no activity. Remove stale label or comment or this will be closed in 7 days
Issue is still relevant
I made a mistake and the converter didn't load
after correction, there are results
This issue is stale because it has been open 30 days with no activity. Remove stale label or comment or this will be closed in 7 days
Issue is still relevant
@Koenkk please open this issue
@evsmorodin to properly support this device, you have to figure out all the datapoints: https://www.zigbee2mqtt.io/advanced/support-new-devices/02_support_new_tuya_devices.html
Same hardware here and same problem.
This issue is stale because it has been open 180 days with no activity. Remove stale label or comment or this will be closed in 30 days
@evsmorodin to properly support this device, you have to figure out all the datapoints: https://www.zigbee2mqtt.io/advanced/support-new-devices/02_support_new_tuya_devices.html
Hello, @Koenkk! For a long time there was no time for smart devices. Today I set aside time for this. So, the datapoints for the device are:
{
"result": [
{
"dpId": 1,
"dpName": "Forward Energy Total"
},
{
"dpId": 3,
"dpName": "Month energy"
},
{
"dpId": 4,
"dpName": "Daily energy"
},
{
"dpId": 6,
"dpName": "Phase A"
},
{
"dpId": 7,
"dpName": "Phase B"
},
{
"dpId": 8,
"dpName": "Phase C"
},
{
"dpId": 9,
"dpName": "Total Power "
},
{
"dpId": 10,
"dpName": "Fault"
},
{
"dpId": 11,
"dpName": "Frozen set"
},
{
"dpId": 16,
"dpName": "Switch"
},
{
"dpId": 17,
"dpName": "Alarm set"
},
{
"dpId": 18,
"dpName": "Meter ID"
},
{
"dpId": 20,
"dpName": "Clear event"
},
{
"dpId": 21,
"dpName": "Forward Energy T1"
},
{
"dpId": 22,
"dpName": "Forward Energy T2"
},
{
"dpId": 23,
"dpName": "Forward Energy T3"
},
{
"dpId": 24,
"dpName": "Forward Energy T4"
}
],
"t": 1715425098886,
"success": true,