KlausT

Results 282 comments of KlausT

The system cannot find the path specified. ? Where does this come from?

ok, another idea: maybe it's the 2 second timeout of Windows: [Timeout Detection and Recovery](https://docs.microsoft.com/en-us/windows-hardware/drivers/display/timeout-detection-and-recovery) In this case you could either decrease the intensity, or change the timeout to 10...

Since this is a fork of a very old ccminer version, there has never been an API. I will probably not add it in the near future.

So far nobody has complained here about this limit. At the time this code was written it was not possible to have more than 8 cards. It still isn't possible...

I have added MAX_GPU now with release 2.05 :-)

I forgot to replace one hardcoded 8 with MAX_GPU. That was causing the "invalid argument". Also fixed a bug in the -d option

I wish ccminer would crash here on my system, so I can fix it, but it's running just fine here.

I have found a possible reason why it crashes. If you would like to test it: [ccminer-819crashfix-cuda91-x64.zip](https://github.com/KlausT/ccminer/files/1629052/ccminer-819crashfix-cuda91-x64.zip)

I was just wondering if ccminer crashes while trying to exit, or if the crash happens while waiting. For some reason it doesn't crash on my system when I do...