HeishaMon icon indicating copy to clipboard operation
HeishaMon copied to clipboard

New heat pump multi split model

Open pvvn3d opened this issue 2 years ago • 13 comments

Hello, Im using Heishamon with EcoFlex model. Its 8kW all in one model + duct type air conditioner. Outdoor unit is a multisplit one (CU-2WZ71YBE5).

All works great. Model for Heisha is unknown and also i dont see data from duct unit. I suspect we can read that data from duct unit because in service cloud i can see it.

So, if i get small help how to check/read this data i can do that for Heisha project upgrade.

pvvn3d avatar Nov 08 '23 13:11 pvvn3d

First , could you Togle hexdump log , and pass from Console all lines with hex values , with are comming just after "Received 203 bytes data" ?

MiG-41 avatar Nov 08 '23 14:11 MiG-41

And please share the data which is working now. Please also show http://heishamon.local/debug hexdump

IgorYbema avatar Nov 08 '23 14:11 IgorYbema

Ok, here is the hexdump: data: 71 C8 01 10 56 55 52 49 00 A5 00 01 00 00 00 00 00 00 00 00 59 15 11 55 96 15 55 55 55 99 02 00 data: 00 00 00 00 00 00 7B 80 80 80 B4 71 71 FF 99 00 00 00 00 00 00 00 00 00 00 00 80 85 5B 8A 85 85 data: D0 7B 78 1F 7E 1F 1F 79 79 8D 8D A7 9B 71 8F B7 A3 7B 8F 94 84 7B 8F 8A 94 9E 8F 8A 94 9E 85 8F data: 8A 15 79 7A BC 3D 7E 7C 0B 7C 7E A8 00 00 55 75 55 21 A9 15 59 05 1B 12 66 09 00 00 00 00 00 00 data: 00 E2 D4 0D 53 88 02 D5 0C 59 88 97 00 AE 86 97 97 32 32 9A AC 32 32 32 7B 9A 97 8D 96 96 86 85 data: 80 80 8A 30 01 01 01 01 01 B9 08 29 5B 01 01 79 79 01 01 45 11 00 01 0D 00 46 00 00 0B 00 00 09 data: 01 01 01 01 01 01 01 02 00 00 11

And here is a data from heisha monitor:

TOP0 Heatpump_State 1 On
TOP1 Pump_Flow 9.44 l/min
TOP2 Force_DHW_State 0 Disabled
TOP3 Quiet_Mode_Schedule 0 Disabled
TOP4 Operating_Mode_State 0 Heat
TOP5 Main_Inlet_Temp 23.50 °C
TOP6 Main_Outlet_Temp 24 °C
TOP7 Main_Target_Temp 31 °C
TOP8 Compressor_Freq 25 Hz
TOP9 DHW_Target_Temp 52 °C
TOP10 DHW_Temp 46 °C
TOP11 Operations_Hours 3328 hours
TOP12 Operations_Counter 4421 count
TOP13 Main_Schedule_State 0 Disabled
TOP14 Outside_Temp 6 °C
TOP15 Heat_Energy_Production 200 Watt
TOP16 Heat_Energy_Consumption 600 Watt
TOP17 Powerful_Mode_Time 0 Off
TOP18 Quiet_Mode_Level 0 Off
TOP19 Holiday_Mode_State 0 Off
TOP20 ThreeWay_Valve_State 0 Room
TOP21 Outside_Pipe_Temp 4 °C
TOP22 DHW_Heat_Delta -6 K
TOP23 Heat_Delta 4 K
TOP24 Cool_Delta 5 K
TOP25 DHW_Holiday_Shift_Temp -15 K
TOP26 Defrosting_State 0 Disabled
TOP27 Z1_Heat_Request_Temp 0 °C
TOP28 Z1_Cool_Request_Temp 0 °C
TOP29 Z1_Heat_Curve_Target_High_Temp 39 °C
TOP30 Z1_Heat_Curve_Target_Low_Temp 27 °C
TOP31 Z1_Heat_Curve_Outside_High_Temp 15 °C
TOP32 Z1_Heat_Curve_Outside_Low_Temp -15 °C
TOP33 Room_Thermostat_Temp 22 °C
TOP34 Z2_Heat_Request_Temp 0 °C
TOP35 Z2_Cool_Request_Temp 0 °C
TOP36 Z1_Water_Temp -78 °C
TOP37 Z2_Water_Temp -78 °C
TOP38 Cool_Energy_Production 0 Watt
TOP39 Cool_Energy_Consumption 0 Watt
TOP40 DHW_Energy_Production 0 Watt
TOP41 DHW_Energy_Consumption 0 Watt
TOP42 Z1_Water_Target_Temp 31 °C
TOP43 Z2_Water_Target_Temp 44 °C
TOP44 Error No error Error
TOP45 Room_Holiday_Shift_Temp -15 K
TOP46 Buffer_Temp -78 °C
TOP47 Solar_Temp -78 °C
TOP48 Pool_Temp -78 °C
TOP49 Main_Hex_Outlet_Temp 25 °C
TOP50 Discharge_Temp 24 °C
TOP51 Inside_Pipe_Temp 24 °C
TOP52 Defrost_Temp 4 °C
TOP53 Eva_Outlet_Temp 0 °C
TOP54 Bypass_Outlet_Temp 0 °C
TOP55 Ipm_Temp 10 °C
TOP56 Z1_Temp 24 °C
TOP57 Z2_Temp -128 °C
TOP58 DHW_Heater_State 0 Blocked
TOP59 Room_Heater_State 0 Blocked
TOP60 Internal_Heater_State 0 Inactive
TOP61 External_Heater_State 0 Inactive
TOP62 Fan1_Motor_Speed 430 r/min
TOP63 Fan2_Motor_Speed 0 r/min
TOP64 High_Pressure 18.0 Kgf/cm2
TOP65 Pump_Speed 2100 r/min
TOP66 Low_Pressure 0 Kgf/cm2
TOP67 Compressor_Current 3.6 Ampere
TOP68 Force_Heater_State 0 Inactive
TOP69 Sterilization_State 0 Inactive
TOP70 Sterilization_Temp 60 °C
TOP71 Sterilization_Max_Time 60 Minutes
TOP72 Z1_Cool_Curve_Target_High_Temp 15 °C
TOP73 Z1_Cool_Curve_Target_Low_Temp 10 °C
TOP74 Z1_Cool_Curve_Outside_High_Temp 30 °C
TOP75 Z1_Cool_Curve_Outside_Low_Temp 20 °C
TOP76 Heating_Mode 0 Comp. Curve
TOP77 Heating_Off_Outdoor_Temp 20 °C
TOP78 Heater_On_Outdoor_Temp -5 °C
TOP79 Heat_To_Cool_Temp 15 °C
TOP80 Cool_To_Heat_Temp 10 °C
TOP81 Cooling_Mode 0 Comp. Curve
TOP82 Z2_Heat_Curve_Target_High_Temp 55 °C
TOP83 Z2_Heat_Curve_Target_Low_Temp 35 °C
TOP84 Z2_Heat_Curve_Outside_High_Temp 15 °C
TOP85 Z2_Heat_Curve_Outside_Low_Temp -5 °C
TOP86 Z2_Cool_Curve_Target_High_Temp 15 °C
TOP87 Z2_Cool_Curve_Target_Low_Temp 10 °C
TOP88 Z2_Cool_Curve_Outside_High_Temp 30 °C
TOP89 Z2_Cool_Curve_Outside_Low_Temp 20 °C
TOP90 Room_Heater_Operations_Hours 69 hours
TOP91 DHW_Heater_Operations_Hours 10 hours
TOP92 Heat_Pump_Model 255 unknown
TOP93 Pump_Duty 93 Duty
TOP94 Zones_State 0 Zone1 active
TOP95 Max_Pump_Duty 254 Duty
TOP96 Heater_Delay_Time 10 Minutes
TOP97 Heater_Start_Delta -4 K
TOP98 Heater_Stop_Delta -2 K
TOP99 Buffer_Installed 0 Disabled
TOP100 DHW_Installed 1 Enabled
TOP101 Solar_Mode 0 Disabled
TOP102 Solar_On_Delta 10 K
TOP103 Solar_Off_Delta 5 K
TOP104 Solar_Frost_Protection 5 °C
TOP105 Solar_High_Limit 80 °C
TOP106 Pump_Flowrate_Mode 0 DeltaT
TOP107 Liquid_Type 0 Water
TOP108 Alt_External_Sensor 0 Disabled
TOP109 Anti_Freeze_Mode 1 Enabled
TOP110 Optional_PCB 0 Disabled
TOP111 Z1_Sensor_Settings 0 Water Temperature
TOP112 Z2_Sensor_Settings 0 Water Temperature
TOP113 Buffer_Tank_Delta 5 K
TOP114 External_Pad_Heater 0 Disabled

All data is looking good, except one topic :

TOP36 Z1_Water_Temp

I have 1 zone pump option, dont have additional zone and optional pcb board installed.

For now i using heisha in "listen only mode" but few days ago im using only heisha to control heat pump. Thing i tested: Basic control eg. on/off, temperatures control, silent modes, powerful mode is working good. Parameters for pump speed, heat delta also works.

Thanks for your interest, i'm appreciated that.

pvvn3d avatar Nov 08 '23 21:11 pvvn3d

I can see , that CZ-TAW1 requesting extra data... Do you see in log similar hexlog , but starts from "71 C8 01 21 ...." (these 21 as 4th byte is difference)

If yes , could you please pass booth from the same time ? ( so also these what is passed already)

I believe 0x21 is only used for the K/L versions. Maybe this duct extensions uses another value. To be sure we need the dump the CZ-taw1 from his system.

@pvvn3d please connect the cz-taw1 back and put heishamon on listen only. Then copy paste some console log from heishamon when it is running together with cz-taw1

IgorYbema avatar Nov 09 '23 06:11 IgorYbema

Yes , looks like after reboot CZ-TAW1 is not asking anymore for 0x21 ,when i feed it with this querty, probably some restovers from L version... So nevermind. @pvvn3d ,can you tell exact name of this additional datas for duct in service cloud ?

Also would be good ,if you made a PR in here filling all datas: https://github.com/Egyras/HeishaMon/blob/master/HeatPumpType.md I cen see , that service cloud is recognizing it as: IDU:WH-ADF0309J3E5CM ODU:CU-2WZ71YBE5

EDIT: And for your information TOP36 is valid , when you have optional PCB( then Water temp zone 1 sensor is obligatory) , so everything ok.

MiG-41 avatar Nov 09 '23 07:11 MiG-41

@IgorYbema Both devices is already connected all the time. When i write hex dump in 1st post it is also connected in that way. How can i read hex dump from cz-taw module like you suggested ?

@MiG-41 I'm trying to get access to service cloud but my installer does not really want to provide access. But i'm working on it, if i must i change installer to another one :) When i get this acces i let you know immediately.

pvvn3d avatar Nov 10 '23 10:11 pvvn3d

Ok , you wrote ,that in service cloud you see some data for duct unit , thought that you have acces to it.... Becouse from your querty ,with i send to Service Cloud i can't see anything more ... Only standard data for HP.

MiG-41 avatar Nov 10 '23 13:11 MiG-41

I see it on my installer pc... To check it you need to have instant acces to the duct values or screenshot will be enaught ?

pvvn3d avatar Nov 10 '23 13:11 pvvn3d

Screenshot enough..

MiG-41 avatar Nov 10 '23 13:11 MiG-41

I check my gallery on phone and i found it... _20231110_144929

Its in polish language but i guessing by your name you are pole :)

For other one starting from left upper corner of duct table is: Status : on/off Mode : Heat/Cool/Dry/Went Temperature set: 23 Fan speed: nanoeX: on/off ECONAVI: Outside temperature: 1 Error:

Thanks

pvvn3d avatar Nov 10 '23 13:11 pvvn3d

In service cloud i have only upper part , no below table ( this is not a combined picture ?) In this case looks like this inner unit S-71WF3E is communicating with CZ-TAW1 other way... Please past log ( with hexdump switched) ,as @IgorYbema asked :

@pvvn3d please connect the cz-taw1 back and put heishamon on listen only. Then copy paste some console log from heishamon when it is running together with cz-taw1

MiG-41 avatar Nov 10 '23 14:11 MiG-41

In service cloud ? How can you see my pump in service cloud? :o This ofcourse not combined picture. Here is log from heisha console (cz-taw i also connectd): Sun Nov 12 11:59:45 2023 (485579284): Heishamon stats: Uptime: 5 days 14 hours 52 minutes 59 seconds ## Free memory: 75% ## Heap fragmentation: 3% ## Max free block: 28808 bytes ## Free heap: 29552 bytes ## Wifi: 96% (RSSI: -52) ## Mqtt reconnects: 5 ## Correct data: 99.99% Sun Nov 12 11:59:46 2023 (485580554): Received 203 bytes data Sun Nov 12 11:59:46 2023 (485580558): data: 71 C8 01 10 56 55 52 49 00 65 00 01 00 00 00 00 00 00 00 00 59 15 11 55 96 15 55 55 55 99 02 00 Sun Nov 12 11:59:46 2023 (485580564): data: 00 00 00 00 00 00 85 80 80 80 B4 71 71 FF 99 00 00 00 00 00 00 00 00 00 00 00 80 85 5B 8A 85 85 Sun Nov 12 11:59:46 2023 (485580576): data: D0 7B 78 1F 7E 1F 1F 79 79 8D 8D A7 9B 71 8F B7 A3 7B 8F 94 85 7B 8F 8A 94 9E 8F 8A 94 9E 85 8F Sun Nov 12 11:59:46 2023 (485580589): data: 8A 15 79 7A BC 3D 7E 7C 0B 7C 7E A8 00 00 55 75 55 21 A9 15 59 05 11 12 66 09 00 00 00 00 00 00 Sun Nov 12 11:59:46 2023 (485580601): data: 00 E2 D4 0D 53 88 02 D5 0C 59 88 A4 00 AB 86 9F A4 32 32 A4 AC 32 32 32 85 A4 A4 B7 96 9F 80 80 Sun Nov 12 11:59:46 2023 (485580613): data: 80 80 99 75 01 3B 3E 01 01 55 16 41 82 46 01 51 01 01 01 68 11 00 2D 0D 00 46 00 00 0B 00 00 09 Sun Nov 12 11:59:46 2023 (485580625): data: 01 0E 29 01 01 01 01 02 00 00 01 Sun Nov 12 11:59:46 2023 (485580631): Checksum and header received ok! Sun Nov 12 11:59:46 2023 (485580646): received TOP65 Pump_Speed: 3200

Comunication between units looks like follows: Duct unit is connected only to outdoor unit (communication and power) Tank unit is also connected to outdoor unit (communication and power) Main power is connected to tank unit. I have service manual for this model if you need that.

If you need more complicated information i think its not problem for me because im a automatician/electrician. But in ESP and similar things im a newbie..

pvvn3d avatar Nov 12 '23 12:11 pvvn3d

I can't see your pump in Service Cloud . I'm sending your responce to service cloud , with gives my HP identical to yours ( only type , so it is not precisly yours). We need some more logs , then only one answer , especialy during start of CZ-TAW1 ( power up) , then there is some handshake with could be interesting , and enything else then "71 C8 01 10 ..." Best ,if you make a log file ,when you attach CZ-TAW1 to power. Could you join slack ? ( link in github) ? https://join.slack.com/t/panasonic-wemos/shared_invite/enQtODg2MDY0NjE1OTI3LTgzYjkwMzIwNTAwZTMyYzgwNDQ1Y2QxYjkwODg3NjMyN2MyM2ViMDM3Yjc3OGE3MGRiY2FkYzI4MzZiZDVkNGE

MiG-41 avatar Nov 12 '23 16:11 MiG-41