Current Behavior
Update from 2.10.1 to 2.10.2 using TXBuddy, radio goes to Emergency Mode. Trainer SBUS ceases to function. Roll back to 2.10.1 and function is restored.
Expected Behavior
Behave like it did in 2.10.1
Steps To Reproduce
Initial instance: Updated to 2.10.2. Had receiver connected to module bay pins. Trainer/SBUS selected for model. Has been working with 2.10.1 for months. No EM in first few boots. No response from slave TX. Noted I had SPort on RX connected, so did a hot swap to SBus RX port. Radio went into EM. No response when using SBUS. Rolled TX back to 2.10.1, and trainer SBUS function worked again. Tried a new flash to 2.10.2, with nothing connected in module bay. Active model was the plane with trainer-SBUS selected. On first boot, radio went into EM. Subsequent boots and radio did not EM, but again no slave TX response with RX connected to module bay (correctly, this time). Again rolled back to 2.10.1 and all worked normally.