Hbm-s-Nuclear-Tech-GIT icon indicating copy to clipboard operation
Hbm-s-Nuclear-Tech-GIT copied to clipboard

Crude oil vanishes when plugged into a Boiler

Open Kurvastan opened this issue 2 years ago • 1 comments

when you have a tank, you fill it up completely with crude oil and then you take a Universal Duct and plug it into a Boiler, set it to extract with a screwdriver, it will fill up the internal buffer of the Boiler (8000mb) and then it will proceed to void the remaining 248 buckets of Crude Oil idk if it does this for anything else, this is the only thing i experienced it on, also i'm playing on 1.12.2

Kurvastan avatar May 08 '22 14:05 Kurvastan

That's an unfortunate oversight on my part. You can use the tank export control instead, that works correctly.