Note reset on transport stop (Cardinal VST3 23.02, FL Studio 21, Ableton Live 11 Lite, Win11)

Open frankgrimy opened this issue 2 years ago • 5 comments

In both DAWs, while the transport is playing notes, the plugin sounds fine, but when the transport stops and any note is still being played, the plugin changes its sound to C (C4 IIRC), during the release phase of the ADSR envelope. It might be due to how the plugin handles MIDI Note Off events.

frankgrimy avatar Mar 09 '23 16:03 frankgrimy

Or it might be the patch itself. Would it be possible to share it?

GBaige avatar Mar 09 '23 17:03 GBaige

Or it might be the patch itself. Would it be possible to share it?

Yeah. It's the default preset for Cardinal Synth. Default.zip

frankgrimy avatar Mar 09 '23 20:03 frankgrimy

Oh, it's just the default patch?

I cannot reproduce this issue. REAPER v6.67, Cardinal VST3 (main) 23.02.

GBaige avatar Mar 10 '23 04:03 GBaige

Could you try it in any of the DAWs I've mentioned? (ideally FL Studio, the one I use the most)

frankgrimy avatar Mar 10 '23 15:03 frankgrimy

Can confirm this occurs in FL Studio v21.0.2 [build 3399], Cardinal VST3 (synth) 23.02.

Upon transport stop, the V/Oct coming from the DAW is reset to C5 while the envelope is still running.

It seems as though the DAW itself is causing this, so it may not be an issue with Cardinal.

image To remedy it, you may wire the V/Oct output from Host MIDI to a sample-and-hold utility, and have it sample-and-hold the incoming signal every time a note is played. Then, patch the output to the V/Oct input in your oscillator, as shown above.

The V/Oct may reset at the Host MIDI output, but the sample-and-hold utility will retain the signal from the last played note upon transport stop.

GBaige avatar Mar 11 '23 04:03 GBaige