Yes, but at the moment, it seems like the only choices of commands I have at the TCL level are fto create chip/block, none to add to existing data.

I have 2 def files containing different information for the same block. I want to load both def files resulting in 1 block containing the combination of data from both...

Given that there are no rails (FP_PDN_ENABLE_RAILS='0'), then there are no transistors being supplied off these segments of metal. If rails are enabled, there is a connection to these stripes...

@donn - concerning the original issue you raised: Straps are placed over the stdcell rows. For this testcase the stdcell rows are continuous across the entire design, hence the straps...

@donn The macro rgb_mixer instantiated by pdngen.tar.gz has blockages up to met3, whereas the macro wrapped_rgb_mixer instantiated by working.tar.gz has blockages up to met4. The fact that there are any...

The PSM messages are PDNSim detailing the instances that it sees as not being connected to power and/or ground. There are several possible root causes: 1. The floorplan is too...

The pdngen code was updated to not require the specification of power_pins and ground_pins, insterad the code would look at all the pins on the macro for signal types POWER...