CaPTk
CaPTk copied to clipboard
Perfusion alignment doesn't output nii.gz & please update usage
Describe the bug perfusion alignment doesn't output nii.gz
To Reproduce
PerfusionAlignment -i $input -d $inputdcm -c $t1ce -b 15 -a 30 -e 0.045 -o $PWD/out_AAAA
outputs 2 files, original_curve.csv and revised_curve.csv Original_curve.csv seems correct with 45 timepoints but revised_curve.csv only has 2. It also does not output a nii.gz
I have put files for you reference here:
/cbica/home/sakoc/comp_space/Saima/20190930_perfalignment
CaPTk Version 1.7.3 Alpha
Desktop (please complete the following information): centos7 on cbica-cluster
** In addition:
Please update the Usage part of the help (1) several say --dicom file. for -d, is this one .dcm file? (2) echo time -- in what unit? (3) do we need to input a t1ce image? if so, any requirements? Does it need to be in the same space as the DSC?
Updated file path due to request: /cbica/home/sakoc/comp_space/lab/captk/180a/perfalignment
input perfusion: AAAB_perf.nii.gz input t1ce: AAAB_t1ce.nii.gz input dicom folder AAAB_dicom_anonymized
command run:
PerfusionAlignment -i AAAB_perf.nii.gz
-d AAAB_dicom_anonymized/1.3.6.1.4.1.14519.5.2.1.99700540694421948465921560797431588453
-c AAAB_2006.10.28_t1ce.nii.gz -b 15 -a 17 -e 2 -o ./out
Result: 2 csvs in folder out as well as out16.nii.gz - out31.nii.gz in current folder
@saimarathore Could you please take a look at this? I just tried this on windows ( as per @chiharusako earlier comment ) and I see: 1 ) there are multiple output.nii.gz created from 16 - 31 2) 2 csv in output folder. The output revised_curve.csv has 90 entries. The last one is zero.
Is this how it is supposed to work? or are there any bugs? Also tagging @chiharusako