ardupilot icon indicating copy to clipboard operation
ardupilot copied to clipboard

Ardupilot v4.5.1 Batt4 Percentage Issue

Open WaqasRauf opened this issue 1 year ago • 1 comments

Bug report

Issue details

I've updated arduplane from v4.4.4 to v4.5.1, after the update my reventec fuel level sensor is not giving fuel percentage, I've checked voltages they are accurate but somehow ardupilot is unable to translate these voltages to percentage. My fuel sensor is connected on batt4. I've set the parameters as described in ardupilot wiki, I've checked the integration again by downgrading the version to 4.4.4 it's working properly but on 4.5.1 it's percentage is not accurate it's giving -1 in the batt4 percentage parameter.

Version Arduplane v4.5.1

Platform Plane

Airframe type Quad plane (X)

Hardware type CUAV X7+ Pro

Logs

WaqasRauf avatar May 08 '24 07:05 WaqasRauf

Please can you provide a log or parameter set. Which physical pin is the sensor connected to?

IamPete1 avatar May 08 '24 20:05 IamPete1

Dear Peter, Please find the attached dataflash log file. The Reventec Fuel Level Sensor (LS300-225) is connected on Pin 18 and it is configured on BAT4, You can see in the logs battery voltages are there but there is no percentage.

Regards, Waqas 00000044.BIN https://drive.google.com/file/d/1K88H4qcuiDuArMT89GMEEWjSQHSF0sY4/view?usp=drive_web

On Wed, 8 May 2024 at 23:01, Peter Hall @.***> wrote:

Please can you provide a log or parameter set. Which physical pin is the sensor connected to?

— Reply to this email directly, view it on GitHub https://github.com/ArduPilot/ardupilot/issues/27017#issuecomment-2101330357, or unsubscribe https://github.com/notifications/unsubscribe-auth/AMSK7CY6TGQXCQ2KI4AP3D3ZBJ777AVCNFSM6AAAAABHMNO532VHI2DSMVQWIX3LMV43OSLTON2WKQ3PNVWWK3TUHMZDCMBRGMZTAMZVG4 . You are receiving this because you authored the thread.Message ID: @.***>

WaqasRauf avatar May 15 '24 09:05 WaqasRauf

Fix here: https://github.com/ArduPilot/ardupilot/pull/27099

IamPete1 avatar May 19 '24 13:05 IamPete1