WLED icon indicating copy to clipboard operation
WLED copied to clipboard

Usermod Updated: Internal Temperature V2

Open adamsthws opened this issue 8 months ago • 5 comments

Hello!

Please may I request to add the following improvement to the usermod: 'Internal Temperature V2'...

Added high temperature indicator/action

  • A configurable preset is activated when the internal temperature raises above a configurable threshold temperature.

  • When the internal temperature falls back below the threshold, the previously active preset is re-activated.

  • If the preset is set to -1, no preset is triggered when temperature rises above the threshold.

  • A small temperature buffer prevents frequent toggling between states when the temperature is close to the threshold. (The reset threshold is automatically calculated to be two degrees lower than whatever the activation threshold is set to).

  • To prevent the user setting the loop interval too low, a minimum allowable interval has been added.

To do

  • In a later phase I plan to add isAboveThreshold to MQTT.

Thankyou! Adam Matthews

adamsthws avatar Jun 26 '24 19:06 adamsthws