ble
ble copied to clipboard
Duplicated functionality in GapAdvertisingParams and GapScanningParams
GapAdvertisingParams and GapScanningParams use MSEC_TO_ADVERTISEMENT_DURATION_UNITS()
and MSEC_TO_SCAN_DURATION_UNITS()
respectively to convert from milliseconds to units of 0.625. However, these two functions do exactly the same operation:
return (durationInMillis * 1000) / UNIT_0_625_MS;
Therefore, this functionality is duplicated. Perhaps it should be included in a common location such as blecommon.h or BLEProtocol? These conversions are necessary because those are the units that the BLE specification uses, they are not specific to advertising or scanning params.
ARM Internal Ref: IOTSFW-1809