no energy values since update 9
Unfortunately, since update 9 I no longer have any energy values for my ECO TEC PLUS gas boiler with a VR 940F internet module. The energy value has been at 25kWh for days and no new values are coming in. I have already reinstalled and reconfigured the MyVaillant application several times without success. If I install an old version 8.X, they will come in again.
There are several posts were this problem is discussed...
https://github.com/signalkraft/mypyllant-component/issues/256#issuecomment-2571775071
https://github.com/signalkraft/mypyllant-component/issues/282#issuecomment-2599627649
I have the same problem. However, only since today. I have version 0.9.1. Could it perhaps be because there are server problems at Vaillant?
I read that you should set the interval in the options, otherwise Vailland will block you if you query the data too often. I increased the time from 60 seconds to 600 seconds, unfortunately without success. The data still shows 0.
I read that you should set the interval in the options, otherwise Vailland will block you if you query the data too often. I increased the time from 60 seconds to 600 seconds, unfortunately without success. The data still shows 0.
![Image] (https://github.com/user-attachments/assets/9287be1c-c6c3-407d-9039-d3cc79284d13)![Image] (https://github.com/user-attachments/assets/d391a2ea-5483-4068-876e-fdf79de0cfe3)
600s is a very short time. I had success setting up at least 1 hour (3600s) . Now to be sure I use 7200s so I don't have any more problems
That's my attitude, I've never done anything about it. The last few weeks have been normal and today only 2x data came in
I have now deleted the My Vaillant integration and waited for more than 24 hours. I have reinstalled the My Vaillant again. I have increased the update interval value from 60 to 7200 seconds. Unfortunately, I only received one value in the My Vaillant app after the first registration, after 24 hours. Now I have been getting no new energy values for hours. What could be the problem?
You must set a value for "Intervall zwischen Energiedaten Updates". If it is none, the plugin will only query energy consumption metrics on initialization. I think it is supposed to be 15min (value 900) and 60min (3600) as the vaillant API used delivers energy data only on hourly intervals in buckets like (energy consumed between 03:00 and 04:00 was xxx kWh). So setting a high update rate will still yield only one different value per hour but you might then hit the vaillant rate limits.
@Ilja-87 still an issue?
@signalkraft think we can close this one as @Ilja-87 does not have an issue anymore