Riccardo Zulian
Riccardo Zulian
First inverter is working fine, but the second added as a new hub is not ``` 2024-08-28 18:58:45.898 DEBUG (MainThread) [custom_components.solaredge_modbus_multi.hub] Disconnectng from 192.168.1.8:502 (clear_client=False). 2024-08-28 18:58:56.115 DEBUG (MainThread) [custom_components.solaredge_modbus_multi.hub]...
I don’t have the web setapp on my inverters. I can confirm that the unit ID was working with the other component and they were 1 and 3 I’ve tryed...
BTW, this was my pull request with some technical detail about my case and the support for multiple inverters https://github.com/erikarenhill/solaredge-modbus-hass/pull/29
From the comment in the PR is see that I had to use the `TcpModbusClient`. https://github.com/erikarenhill/solaredge-modbus-hass/pull/29/files Does this resonate to you?
Could you please check the code in this old PR and see if there is something that can be missing in your code. I remember I had to invest a...
It's working! Thanks