nmakel

Results 114 comments of nmakel

The method described in my previous comment seems to hold up. It has been running now for about 16 hours with a night in between. Once a connection is made...

Nothing too shocking, you can see the diff in the protobuf files in the repo. In the interface a few new options to set (external) power management have been added....

I poll status (for basic inverter stats) every 10 seconds. and maintenance (for power optimizer stats) every 60 seconds. The last time I was working on the new setup the...

Confirmed working on 4.9.30. Nice find!

The inverter talks to SolarEdge over https, and in the past I've only seen the one connection. Through this channel it sends telemetry for the monitoring portal, and receives messages...

Heads up that the firmware that dropped today (4.9.33) contains a fix for the above method.

> Any clues what is the response from the web server with this new 4.9.33 firmware? Is it a http response code? If so, it should still be possible to...

> Well, it looks like it is no so easy... > > There are two main components called core and pmanager (healthcheck running for these periodically) > > There is...

> Possible future SolarEdge system owner here. All the players (Enphase, APSytems, Tigo, SolarEdge, SMA) are engaged in the data lock down game in one shape or form. I'm just...

> Does this mean it’s impossible to extract the encryption keys with the latest firmware? Or is the rs485 option still working? I'm guessing that's a question better asked in...