Nick
Nick
Not quite sure I follow, Am I right in thinking the issue is that UEs get allocated varied subnet masks? Certain types of UEs request more than one IP, for...
@haroon3rd - Would be useful if you can share a PCAP showing the S1 / GTP messaging, I assume you're using the IP pool, have you tried setting Static IPs...
Looks like those handsets use a Qualcomm MSM8998 Snapdragon chip, so the documentation probably won't include any of the technical info. Please share a PCAP of the attach and the...
You cannot have a default bearer with a guaranteed bit rate. You will need to define Traffic Flow Templates on an APN and then link that to the GBR. For...
If you can't ping "pcscf" it is because your DNS server does not have an entry for that domain name. Looking at the previous logs it also looks like Kamailio...
> As discussed in #1332 the use of 999/99 seems to break iPhones. So it's probably a bad choice for the beginners tutorial. Hey Julian! Great contribution so far, on...
PCAP?
@greigdp - I attempted to help Davied here, as he wasn't willing to share a PCAP of the real thing, so I just hacked an MSISDN AVP into the ULR,...
It looks like your S11 interface isn't coming up, so the MME is unable to request the S-GW setup a bearer. Can you please share a trace with GTP-U as...