comfoconnect icon indicating copy to clipboard operation
comfoconnect copied to clipboard

PDID 226 shows modulation

Open vain90 opened this issue 4 years ago • 3 comments

Maybe you've already found that, but yesterday I've seen that the PDID 226 changed after my Q350 detects more humidity and goes into "humidity control". (Comfort controls)

After a little of testing it seems that the value ist depending on which Mode you are.

Away: 0 Reduced: 100 Normal: 200 Intensive: 300

And in this modes the system can modulate. My Q350 was in mode Normal (200) and leveled up the Airflow.

In this moment the PDID 226 shows 300 at the beginning and Reduced over time.

200 205 206 207 206 205 200 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 214 213 212 211 210 209 208 207 206 200

You have to read backwards. At the same time the PDID 225 change from 1 to 2. Maybe the 225 shows the reason for the modulation. (Comfort controls)

vain90 avatar Feb 02 '21 07:02 vain90

Ah, sorry didn't see the #10 My bad!

vain90 avatar Feb 02 '21 08:02 vain90

can you explain more about what do you mean 'read backwards' ?

gytisgreitai avatar Dec 29 '21 14:12 gytisgreitai

@gytisgreitai oh the „read backwards“ refers to my values I posted.

You have to read from back to front in order to be in the correct chronological sequence. The values I’ve posted were created when someone was just taking a shower. You can see the modulation value rises slightly at first and rises rapidly to 300. After that you can see the KWL is dissipates the increased humidity gradually.

vain90 avatar Dec 29 '21 19:12 vain90

Thanks all! I've added this info here: https://github.com/michaelarnauts/aiocomfoconnect/blob/master/docs/PROTOCOL-PDO.md#overview-of-known-sensors

michaelarnauts avatar Dec 02 '22 13:12 michaelarnauts