just for the info, Bypass/ECO Mode from docs: Eaton 9E 2000 model :    Eaton 9SX 2000 model :  
it seems we can set some voltage range for both modes like posted in https://github.com/networkupstools/nut/issues/2492#issuecomment-2191108335
> UPS.OutletSystem.Outlet.[1].ConfigApparentPower in vars have only : ``` outlet.1.status: on outlet.desc: Main Outlet outlet.id: 0 outlet.switchable: no ``` cant find it for Eaton 9E in log : 
but found next : ``` hid_lookup_path: 00840004 -> UPS Sep 7 11:34:09 myserver rc.nut: 4.071424#011[D5:3982] hid_lookup_path: 00840018 -> OutletSystem Sep 7 11:34:09 myserver rc.nut: 4.071431#011[D5:3982] hid_lookup_path: 00840020 -> Outlet Sep...
> I'll try to look for the missing proprietary Usage IDs (like ffff00ba) in case you need, posting debug nut log ... [nut debug log.txt](https://github.com/user-attachments/files/17039059/nut.debug.log.txt)
> hey there, finally got the info: > > * ffff00ba = iDesignator (to be added in mge-hid) > * Path: UPS.OutletSystem.Outlet.[x].iDesignator: > ** Labelling of the load segment that...
> if you can extract and highlight these, that would save me some precious time. Do you need only hex number or path or the whole block where unknown?
> the full HID path with the unknown hex Usage ID, similar to UPS.OutletSystem.Outlet.[x].ffff00ba thx just to be sure : this case is ok becouse its found by another id...
> the full HID path with the unknown hex Usage ID, similar to UPS.OutletSystem.Outlet.[x].ffff00ba thx ``` Path: UPS.BatterySystem.Charger.ffff00e9, Type: Feature, ReportID: 0x26, Offset: 8, Size: 8, Value: 2 Path: UPS.OutletSystem.Outlet.[1].ffff00ba,...
> > > the full HID path with the unknown hex Usage ID, similar to UPS.OutletSystem.Outlet.[x].ffff00ba thx > > > > > > just to be sure : this case...