ebusd-configuration
ebusd-configuration copied to clipboard
vSMART configuration
I have created a new file for vSMART configuration (Netatmo device)
address 10: master #2 address 15: slave #2, scanned "MF=Vaillant;ID=SCC00;SW=0500;HW=3903", loaded "vaillant/15.scc.csv"
The aim is to request a pull when it were confirmed
BTW, concerning to configuration file hcmode.inc, lines B510 00 format and fields are far inconsistent with vSMART messages:
"# type (r[1-9];w;u)";circuit;name;[comment];[QQ];ZZ;PBSB;[ID];field1;part (m/s);datatypes/templates;divider/values;unit;comment;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
# HC operation mode;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
*r;;;;;;B504;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
r;;DateTime;Date Time;;;;00;;;"dcfstate;btime;bdate;temp2";;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
r;;Status16;Outside temperature;;;;16;;;temp;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
# HC operation mode2;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
*r;;;;;;B511;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
*uw;;;;;;B510;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
uw;;SetMode;Operation Mode;;;;00;;;hcmode;;;;flowtempdesired;;temp1;;;;hwctempdesired;;temp1;;;;hwcflowtempdesired;;temp0;;;;;;IGN:1;;;;disablehc;;BI0;;;;disablehwctapping;;BI1;;;;disablehwcload;;BI2;;;;;;IGN:1;;;;remoteControlHcPump;;BI0;;;;releaseBackup;;BI1;;;;releaseCooling;;BI2;;;;
#potential last byte: currentmode;s;UCH;"0=off;1=standby;2=heat;3=water";;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
r;;Status01;Vorlauftemperatur/Rücklauftemperatur/Aussentemperatur/WW Temperatur/Speichertemperatur/Pumpenstatus;;;;01;;;"temp1;temp1;temp2;temp1;temp1;pumpstate";;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
r;;Status02;Betriebsart/Maximaltemperatur/ReglerCurrentTEMP/Maximaltemperatur/ReglerCurrentTemp;;;;02;;;"hwcmode;temp0;temp1;temp0;temp1";;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
r;;Status;Status;;;;03;;;"temp;press;press;hcmode2;HEX";;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
*uw;;;;;;B512;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
uw;;StatusCirPump;Status circulation pump;;;;00;;;UCH;"0=off;100=on";;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
New file: "15.scc.csv"
"# type (r[1-9];w;u)";circuit;name;[comment];[QQ];ZZ;PBSB;[ID];field1;part (m/s);datatypes/templates;divider/values;unit;comment;field2;part (m/s);datatypes/templates;divider/values;unit;comment;field3;part (m/s);datatypes/templates;divider/values;unit;comment;field4;part (m/s);datatypes/templates;divider/values;unit;comment;field5;part (m/s);datatypes/templates;divider/values;unit;comment;field6;part (m/s);datatypes/templates;divider/values;unit;comment;field7;part (m/s);datatypes/templates;divider/values;unit;comment
#;SCC;vSMART;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
uw;SCC;WriteModeSCC;Set Mode;10;08;B510;;;;IGN:2;;;Unknown always 00 00;TempSalidaObjetivo;;temp1;;;;TempACSObjetivo;;temp1;;;;;;IGN:2;;;Unknown always ff ff;Flags0;;UCH;;;;;;IGN:2;;;Unknown always ff 00;;;;;;
;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
*r;;;;10;08;B511;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
r;;ReadModeSCC;Operation Mode;;;;00;Temperaturasalida;;temp;;;;TemperaturaentradaACS;;D1B;;;Puede ser la temperatura del agua de entrada?;Tempcircuitoagua;;temp1;;;Va de 17-70 y 95-100;Flags1;;UCH;;;;Flags2;;UCH;;;;;;IGN:1;;;;Flags3;;UCH;;;
;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
*uw;;;;10;08;B512;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
uw;;StatusCirPumpSCC;Status circulation pump;;;;00;;;UCH;"0=off;100=on";;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
# Current errors;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
*r;;;;10;08;B503;00;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
r;;currenterror02;Current errors 02;;;;02;;;errors;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
r;;currenterror03;Current errors 03;;;;03;;;errors;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
r;;currenterror04;Current errors 04;;;;04;;;errors;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
This format is recognized by other devices, or it is misconfigured?
I have a vSMART too! In combination with a Vaillant ecoTEC pro VCW 286/5-3 A (which AFAICT is functionally identical to and just more powerful than a VCW 226/5-3 A).
I'm running ebusd using Docker and am using https://lectronz.com/products/ebus-to-wifi-adapter-module.
My output:
admin@mist ebusd-docker % docker compose up
[+] Running 1/0
(? Container ebusd Recreated 0.1s
Attaching to ebusd
ebusd | 2023-02-18 15:54:18.847 [main error] invalid/unknown argument in env (ignored): readonly
ebusd | 2023-02-18 15:54:18.942 [main notice] ebusd 23.1.23.1 started with auto scan on device esp-ebus.local:3333
ebusd | 2023-02-18 15:54:19.838 [bus notice] bus started with own address 31/36
ebusd | 2023-02-18 15:54:19.838 [bus notice] signal acquired
ebusd | 2023-02-18 15:54:20.806 [bus notice] new master 10, master count 2
ebusd | 2023-02-18 15:54:20.836 [bus notice] new master 03, master count 3
ebusd | 2023-02-18 15:54:20.836 [update notice] received unknown MS cmd: 1008b51009000030ffffff00ff00 / 0101
ebusd | 2023-02-18 15:54:27.330 [update notice] received unknown MS cmd: 1008b5110100 / 086c01100000000001
ebusd | 2023-02-18 15:54:27.632 [update notice] received unknown MS cmd: 1008b5110101 / 092d2e0080ff300000ff
ebusd | 2023-02-18 15:54:30.011 [bus notice] scan 08: ;Vaillant;BAI00;0204;9602
ebusd | 2023-02-18 15:54:30.011 [update notice] store 08 ident: done
ebusd | 2023-02-18 15:54:30.011 [update notice] sent scan-read scan.08 QQ=31: Vaillant;BAI00;0204;9602
ebusd | 2023-02-18 15:54:30.011 [bus notice] scan 08: ;Vaillant;BAI00;0204;9602
ebusd | 2023-02-18 15:54:30.526 [main notice] read common config file vaillant/broadcast.csv
ebusd | 2023-02-18 15:54:30.663 [main notice] read common config file vaillant/scan.csv
ebusd | 2023-02-18 15:54:30.793 [main notice] read common config file vaillant/general.csv
ebusd | 2023-02-18 15:54:30.907 [update notice] received unknown MS cmd: 1008b51009000030ffffff00ff00 / 0101
ebusd | 2023-02-18 15:54:30.918 [main notice] read scan config file vaillant/08.bai.csv for ID "bai00", SW0204, HW9602
ebusd | 2023-02-18 15:54:31.105 [update notice] sent scan-read scan.08 id QQ=31:
ebusd | 2023-02-18 15:54:31.270 [update notice] sent scan-read scan.08 id QQ=31:
ebusd | 2023-02-18 15:54:31.439 [update notice] sent scan-read scan.08 id QQ=31:
ebusd | 2023-02-18 15:54:31.607 [update notice] sent scan-read scan.08 id QQ=31: 21;17;39;0010021849;1300;346020;N4
ebusd | 2023-02-18 15:54:32.043 [main notice] found messages: 202 (2 conditional on 27 conditions, 0 poll, 10 update)
ebusd | 2023-02-18 15:54:32.208 [update notice] sent scan-read scan.08 id QQ=31: 21;17;39;0010021849;1300;346020;N4
ebusd | 2023-02-18 15:54:32.373 [update notice] sent scan-read scan.08 id QQ=31: 21;17;39;0010021849;1300;346020;N4
ebusd | 2023-02-18 15:54:32.541 [update notice] sent scan-read scan.08 id QQ=31: 21;17;39;0010021849;1300;346020;N4
ebusd | 2023-02-18 15:54:32.714 [update notice] sent scan-read scan.08 id QQ=31: 21;17;39;0010021849;1300;346020;N4
ebusd | 2023-02-18 15:54:32.714 [bus notice] scan 08: ;21;17;39;0010021849;1300;346020;N4
ebusd | 2023-02-18 15:54:34.905 [bus notice] scan 15: ;Vaillant;SCC00;0500;3903
ebusd | 2023-02-18 15:54:34.905 [update notice] store 15 ident: done
ebusd | 2023-02-18 15:54:34.905 [update notice] sent scan-read scan.15 QQ=31: Vaillant;SCC00;0500;3903
ebusd | 2023-02-18 15:54:34.905 [bus notice] scan 15: ;Vaillant;SCC00;0500;3903
ebusd | 2023-02-18 15:54:35.077 [update notice] sent unknown MS cmd: 3115b5090124 / 09003231323033323030
ebusd | 2023-02-18 15:54:35.246 [update notice] sent scan-read scan.15 id QQ=31:
ebusd | 2023-02-18 15:54:35.406 [update notice] sent scan-read scan.15 id QQ=31:
ebusd | 2023-02-18 15:54:35.569 [update notice] sent scan-read scan.15 id QQ=31: 21;20;32;0020197223;0932;016140;N2
ebusd | 2023-02-18 15:54:35.569 [bus notice] scan 15: ;21;20;32;0020197223;0932;016140;N2
ebusd | 2023-02-18 15:54:35.707 [main error] unable to load scan config 15: no file from vaillant with prefix 15 matches ID "scc00", SW0500, HW3903
ebusd | 2023-02-18 15:54:35.707 [main error] scan config 15: ERR: element not found
ebusd | 2023-02-18 15:54:37.311 [update notice] received unknown MS cmd: 1008b5110100 / 086c01100000000001
ebusd | 2023-02-18 15:54:37.582 [update notice] received read bai Status01 QQ=10: 22.5;23.0;-;-;24.0;off
ebusd | 2023-02-18 15:54:40.387 [update notice] received read bai Status02 QQ=10: on;60;40.0;70;65.0
ebusd | 2023-02-18 15:54:41.004 [update notice] received update-write bai SetMode QQ=10: auto;24.0;-;-;0;0;0;0;0;0
ebusd | 2023-02-18 15:54:47.412 [update notice] received unknown MS cmd: 1008b5110100 / 086c01100000000001
ebusd | 2023-02-18 15:54:47.682 [update notice] received read bai Status01 QQ=10: 22.5;23.0;-;-;24.0;off
ebusd | 2023-02-18 15:54:51.113 [update notice] received update-write bai SetMode QQ=10: auto;24.0;-;-;0;0;0;0;0;0
ebusd | 2023-02-18 15:54:57.526 [update notice] received unknown MS cmd: 1008b5110100 / 086c01100000000001
ebusd | 2023-02-18 15:54:57.796 [update notice] received read bai Status01 QQ=10: 22.5;23.0;-;-;24.0;off
ebusd | 2023-02-18 15:55:01.095 [update notice] received update-write bai SetMode QQ=10: auto;24.0;-;-;0;0;0;0;0;0
ebusd | 2023-02-18 15:55:03.575 [update notice] received read bai currenterror QQ=10: -;-;-;-;-
ebusd | 2023-02-18 15:55:03.814 [update notice] received unknown MS cmd: 1008b503020002 / 0affffffffffffffffffff
ebusd | 2023-02-18 15:55:04.095 [update notice] received unknown MS cmd: 1008b503020003 / 0a0000ffffffffffffffff
ebusd | 2023-02-18 15:55:04.376 [update notice] received unknown MS cmd: 1008b503020004 / 0affffffffffffffffffff
ebusd | 2023-02-18 15:55:07.584 [update notice] received unknown MS cmd: 1008b5110100 / 086c01100000000001
ebusd | 2023-02-18 15:55:07.853 [update notice] received read bai Status01 QQ=10: 22.5;23.0;-;-;24.0;off
ebusd | 2023-02-18 15:55:10.532 [update notice] received read bai Status02 QQ=10: on;60;40.0;70;65.0
ebusd | 2023-02-18 15:55:11.152 [update notice] received update-write bai SetMode QQ=10: auto;24.0;-;-;0;0;0;0;0;0
ebusd | 2023-02-18 15:55:17.562 [update notice] received unknown MS cmd: 1008b5110100 / 086c01100000000001
ebusd | 2023-02-18 15:55:17.829 [update notice] received read bai Status01 QQ=10: 22.5;23.0;-;-;24.0;off
ebusd | 2023-02-18 15:55:21.261 [update notice] received update-write bai SetMode QQ=10: auto;24.0;-;-;0;0;0;0;0;0
ebusd | 2023-02-18 15:55:26.678 [update notice] received unknown MS cmd: 1008b5110100 / 086c01100000000001
ebusd | 2023-02-18 15:55:26.945 [update notice] received read bai Status01 QQ=10: 22.5;23.0;-;-;24.0;off
ebusd | 2023-02-18 15:55:31.237 [update notice] received update-write bai SetMode QQ=10: auto;24.0;-;-;0;0;0;0;0;0
ebusd | 2023-02-18 15:55:36.735 [update notice] received unknown MS cmd: 1008b5110100 / 086c01100000000001
ebusd | 2023-02-18 15:55:37.005 [update notice] received read bai Status01 QQ=10: 22.5;23.0;-;-;24.0;off
ebusd | 2023-02-18 15:55:39.684 [update notice] received read bai Status02 QQ=10: on;60;40.0;70;65.0
^CGracefully stopping... (press Ctrl+C again to force)
[+] Running 1/1
(? Container ebusd Stopped 2.6s
canceled
admin@mist ebusd-docker %
AFAICT making ebusd discover the config file you posted here should change all those received unknown MS cmd lines into actual information, right?
I'll try to get your CSV loaded now … (the UX of ebusd is rather unique 😅).
Would me enabling raw logging help you confirm things?
Using 15.scc.csv as provided by @gvisol
I did:
cd /Volumes/dev/ebusdgit clone [email protected]:john30/ebusd-configuration.gitcd ebusd-configuration/ebusd-2.1.x/en/vaillant- Copy the CSV provided by @gvisol and paste it in the appropriate file:
pbpaste > 15.scc.csv—as instructed above - Instructed the
ebusddocker container to know about this path by adding todocker-compose.yaml:
volumes:
- /Volumes/dev/ebusd/ebusd-configuration/ebusd-2.1.x/en:/etc/ebusd-configuration
- And then using it:
EBUSD_CONFIGPATH: /etc/ebusd-configuration
docker compose up
Before
ebusd | 2023-02-18 15:54:35.569 [bus notice] scan 15: ;21;20;32;0020197223;0932;016140;N2
ebusd | 2023-02-18 15:54:35.707 [main error] unable to load scan config 15: no file from vaillant with prefix 15 matches ID "scc00", SW0500, HW3903
ebusd | 2023-02-18 15:54:35.707 [main error] scan config 15: ERR: element not found
After
busd | 2023-02-20 20:20:05.948 [bus notice] scan 15: ;Vaillant;SCC00;0500;3903
ebusd | 2023-02-20 20:20:05.948 [update notice] store 15 ident: done
ebusd | 2023-02-20 20:20:05.948 [update notice] sent scan-read scan.15 QQ=31: Vaillant;SCC00;0500;3903
ebusd | 2023-02-20 20:20:05.948 [bus notice] scan 15: ;Vaillant;SCC00;0500;3903
ebusd | 2023-02-20 20:20:06.118 [update notice] sent unknown MS cmd: 3115b5090124 / 09003231323033323030
ebusd | 2023-02-20 20:20:06.284 [update notice] sent scan-read scan.15 id QQ=31:
ebusd | 2023-02-20 20:20:06.454 [update notice] sent scan-read scan.15 id QQ=31:
ebusd | 2023-02-20 20:20:06.623 [update notice] sent scan-read scan.15 id QQ=31: 21;20;32;0020197223;0932;016140;N2
ebusd | 2023-02-20 20:20:06.623 [bus notice] scan 15: ;21;20;32;0020197223;0932;016140;N2
ebusd | 2023-02-20 20:20:06.680 [main error] error reading scan config file vaillant/15.scc.csv for ID "scc00", SW0500, HW3903: ERR: invalid argument, vaillant/15.scc.csv:14: ERR: invalid argument, missing field map
ebusd | 2023-02-20 20:20:06.680 [main error] scan config 15: ERR: invalid argument
ebusd | 2023-02-20 20:20:06.983 [update notice] received update-write bai SetMode QQ=10: auto;25.0;-;-;0;0;0;0;0;0
👆 Your 15.scc.csv seems to have loaded, but it's still complaining. Perhaps I have a different vSMART model. I'm in Belgium — I have the impression Vaillant does slightly different products for each m
P.S.: pointed https://github.com/john30/ebusd/discussions/832 to this issue.
BTW, https://github.com/john30/ebusd/discussions/781 really helps connect the different parts of ebusd.
Hi, thanks both for sharing this. I have tried your CSV but I am getting the following error:
2023-02-20 20:34:02.641 [main error] error reading scan config file vaillant/15.scc.csv for ID "scc00", SW0500, HW3903: ERR: invalid argument, vaillant/15.scc.csv:14: ERR: invalid argument, missing field map
@gvisol I still can't get this to work. Can you upload as a pull request so we can test and comment please
@gvisol I still can't get this to work. Can you upload as a pull request so we can test and comment please
Sure! In fact the version running at home is newer than the one I've uploaded here. Allow me to have spare time and I'll update my progress.
@gvisol I still can't get this to work. Can you upload as a pull request so we can test and comment please
Sure! In fact the version running at home is newer than the one I've uploaded here. Allow me to have spare time and I'll update my progress.
Hi, are you still planning to upload your changes? I am excited to try them out
@gvisol I still can't get this to work. Can you upload as a pull request so we can test and comment please
Sure! In fact the version running at home is newer than the one I've uploaded here. Allow me to have spare time and I'll update my progress.
@gvisol sorry to chase but are you still planning to upload your config as a pull request so we can test?
@gvisol I still can't get this to work. Can you upload as a pull request so we can test and comment please
Sure! In fact the version running at home is newer than the one I've uploaded here. Allow me to have spare time and I'll update my progress.
Could you share your config file? Love to try this out.
HI everybody.
Here is the last update:
# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment,field6,part (m/s),datatypes/templates,divider/values,unit,comment,field7,part (m/s),datatypes/templates,divider/values,unit,comment,field8,part (m/s),datatypes/templates,divider/values,unit,comment,field9,part (m/s),datatypes/templates,divider/values,unit,comment,field10,part (m/s),datatypes/templates,divider/values,unit,comment,field11,part (m/s),datatypes/templates,divider/values,unit,comment,field12,part (m/s),datatypes/templates,divider/values,unit,comment
#,SCC,vSMART,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
*r,SCC,,,10,08,B511,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
r,,ReadModeSCC,Operation Mode,,,,00,Temp_1,,D2C,,,,Temp_2,,UCH,,,,Temp_3,,D1C,,,,Temp_4,,UCH,,,,Flags1,,UCH,,,,,,IGN:1,,,,Flags2,,UCH,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
# Current errors,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
*r,SCC,,,10,08,B503,00,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
r,,currenterror02,Current errors 02,,,,02,,,errors,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
r,,currenterror03,Current errors 03,,,,03,Unknown_4,,UIN,,,,,,UIN,,,,,,UIN,,,,,,UIN,,,,,,UIN,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
r,,currenterror04,Current errors 04,,,,04,,,errors,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
Meanwhile, I am trying to figure out what is temp_1, temp_2, temp_3, temp_4, flags_1 & flags_2 (this one is already undertood!)
I'll keep updated this thread.