Dispa-SET icon indicating copy to clipboard operation
Dispa-SET copied to clipboard

The `StartUpTime` parameter is never used

Open matteodefelice opened this issue 6 years ago • 2 comments

The Dispa-SET documentation includes the parameter StartUpTime among the input fields needed for the power plants and in fact it is present in the power plants files under the Database folder. However, I couldn't find any reference to it in the model formulation: if the parameter is not used it must be removed to avoid to confuse the users (like me, I spent time to try to understand how to characterise that field before realising that probably is not used).

matteodefelice avatar Apr 18 '19 12:04 matteodefelice

Indeed, this was used some time ago, but we changed the formualtion.

I will remove it!

squoilin avatar Apr 18 '19 17:04 squoilin

It's the same for minEfficiency and perhaps with NoLoadCost.

matteodefelice avatar May 28 '19 09:05 matteodefelice