autotorio icon indicating copy to clipboard operation
autotorio copied to clipboard

Adding landfill under powerlines sometimes breaks connectivity between poles

Open naikrovek opened this issue 4 years ago • 3 comments

If red and green signal wires are also strung between power poles in a blueprint, putting the blueprint through Autotorio to add landfill under the entities sometimes removes the power lines between power poles, but not the red and green signal wires.

naikrovek avatar Aug 16 '21 11:08 naikrovek

Could you provide an example blueprint? Is this only occurring when there’s at least one red/green wire connected?

demipixel avatar Aug 16 '21 20:08 demipixel

This is the one that was giving me trouble. Adding landfill under this with Autotorio removed many, but not all, of the power wires between poles. Red and green signal wires all remained.

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

naikrovek avatar Aug 17 '21 12:08 naikrovek

You can see the missing wires in https://fbe.teoxoy.com/ once you get the modified blueprint out of Autotorio.

I select the Blueprint Tool, check "Add landfill under entities" paste the BP string in, and click "get blueprint."

naikrovek avatar Aug 17 '21 12:08 naikrovek