metroscope-modeling-library icon indicating copy to clipboard operation
metroscope-modeling-library copied to clipboard

[FEATURE] Internal Faults for the GT and compressor

Open nabily-met opened this issue 2 years ago • 2 comments

Internal faults to be added in MML3 (a literature review may be needed to validate them)

  • [ ] Compressor fouling: reduction of the volumetric flow rate
  • [x] Compressor underperformance: reduction of the isentropic efficiency of the compressor (may be attributed to the compressor fouling)
  • [x] Compressor compression underperformance (may not be needed): to be studied since a reduction in the mass flow rate will definitely decrease the pressure ratio
  • [x] GT turbine underperformance: reduction of the isentropic efficiency of the turbine
  • [ ] ST capacity underperformance: reduction of the stodola coefficient
  • [ ] ST underperformance: reduction of the isentropic efficiency

nabily-met avatar Jan 23 '23 15:01 nabily-met

Already implemented in v3.7.0 :

  • compressor_eta_is decrease
  • compressor_tau decrease
  • gas_turbine_eta_is decrease

pierre-eliep-met avatar Oct 23 '23 12:10 pierre-eliep-met

The two last on stodola turbines should indeed need a litterature review, or a training (I should have one on steam turbines at some point), because I've asked several times if we should model them and got the answer that it is not a usual underperformance on NPPs 🤷

pierre-eliep-met avatar Sep 12 '24 09:09 pierre-eliep-met