Vitocal200S support / XML file configurable
Hello,
I have a Vitocal 200S which uses a different command set (see https://github.com/openv/openv/wiki/Adressen#adressen-um-werte-abzufragen-oder-zu-setzen), which I already used successfully for years in FHEM / VCONTROL.
Would it be possible to make the vito.xml editable so we can add custom commands to allow other devices?
Thanks!
I downloaded a copy of the addon and created a local addon from it, but no matter what I try it completly ignores any changes from the rootfs/etc/vito.xml. I simply changed the payload of an existing command to one that the 200S understands, but it still sends the old payload.
Could it be that the vito.xml is taken from the original vcontrold (installed from the docker file) instead of the provided one?
as far as I understood, you can not modify a file of a installed add-on, as it's running in a container. The only possible configuration is within the config page of the add-on administration in ha. Having this said, I do have exactly the same issue. Also Vitocal 200-S and also migrating from FHEM. :-)
@Alexandre-io would you add the parameters for Vitocal 200-S in your code?
Hi @elasc, could you send me the vito.xml for the 200-S? I will try to find the best way to integrate it into the module.
as far as I understood, you can not modify a file of a installed add-on, as it's running in a container. The only possible configuration is within the config page of the add-on administration in ha. Having this said, I do have exactly the same issue. Also Vitocal 200-S and also migrating from FHEM. :-)
Yes, that is why I installed it as a custom (local) addon and modified the files before installation, but still it seems it is not using the values I set there (maybe the wrong place?)
Hello @here! I just added the ability to customize the vito.xml file. You just need to create the vcontrold directory in the HA configuration files and add the vito.xml file.
cf. https://github.com/Alexandre-io/homeassistant-vcontrol/blob/main/vcontrold/DOCS.md#custom-vitoxml-configuration-file
Does this mean that I the check for the possible device IDs isn't enforced any longer?
Btw, for me the integration of the configuration for the Vitocal200S (device ID 204D) would be very useful as well :-)
very nice @Alexandre-io and great support. I've added the modified vito.xml file as custom file as you've implemented this today. Attached please find my file for 204D (Vitocal 200-S).
Commands are getTempA getTempVListM1 getTempVLsollM1 getTempRL17A getTempSpu getUmschaltventil
A bit hacky; I've also added this device in command getTempVListM2 for reading Vorlaufsolltemperatur Anlage as I could not find an implemented command for this reading. vito.xml.zip
Seems to work, thanks :-)
Hint for others: the vito.xml needs to be saved in /config/vcontrold (/config being the root of the "file editor").
My list of commands:
- getTempA:FLOAT
- getTempVListM1:FLOAT
- getTempVListM2:FLOAT
- getTempVLsollM1:FLOAT
- getTempRL17A:FLOAT
- getTempSpu:FLOAT
- getUmschaltventil:FLOAT
My yaml:
mqtt:
binary_sensor:
- name: Status Umschaltventil
unique_id: vcontroldgetUmschaltventil
state_topic: openv/getUmschaltventil
device_class: running
value_template: "{% if(value|int == '0') %}OFF{% else %}ON{% endif %}"
device:
identifiers: vcontrold
manufacturer: Viessmann
sensor:
- name: Aussentemperatur
unique_id: vcontroldgetTempA
device_class: temperature
state_topic: openv/getTempA
unit_of_measurement: °C
value_template: "{{ value | round(2) }}"
device:
identifiers: vcontrold
manufacturer: Viessmann
- name: Vorlauftemperatur M1
unique_id: vcontroldgetTempVListM1
state_topic: openv/getTempVListM1
device:
identifiers: vcontrold
manufacturer: Viessmann
unit_of_measurement: °C
value_template: "{{ value | round(2) }}"
- name: Vorlauftemperatur M2
unique_id: vcontroldgetTempVListM2
state_topic: openv/getTempVListM2
device:
identifiers: vcontrold
manufacturer: Viessmann
unit_of_measurement: °C
value_template: "{{ value | round(2) }}"
- name: Vorlaufsolltemperatur M1
unique_id: vcontroldgetTempVLsollM1
state_topic: openv/getTempVLsollM1
device:
identifiers: vcontrold
manufacturer: Viessmann
unit_of_measurement: °C
value_template: "{{ value | round(2) }}"
- name: Ruecklauftemperatur 17A
unique_id: vcontroldgetTempRL17A
state_topic: openv/getTempRL17A
device:
identifiers: vcontrold
manufacturer: Viessmann
unit_of_measurement: °C
value_template: "{{ value | round(2) }}"
- name: Speichertemperatur unten
unique_id: vcontroldgetTempSpu
state_topic: openv/getTempSpu
device:
identifiers: vcontrold
manufacturer: Viessmann
unit_of_measurement: °C
value_template: "{{ value | round(2) }}"
I think that some more commands should be adaptable for the Vitocal 200S, but this is a thing for the next days ;-)
Alexandre-io Maybe another idea to extend this issue. How about overwriting the vcontrold.xml or at least parts of it? My vito.xml (found on the internet) uses some custom protocmds, which are not available from vcontrold.
Example:
<command name="setaddr25"> <send>SEND 00 02 $addr $hexlen FA 00;RECV 2 SR</send> </command>
Thanks in advance :-)
I also have a Vitocal 222-S and a Vitotronic 200 Type WO1C (Device ID = 204D)
(Remark: I quite new to homeassistant ;))
In order to use the vito.xml for my device (204D) I followed the steps described above.
- ssh into homeassistant
- created a folder
add-on_configs/vcontrold - copy my file
vito.xmlinto the just created folder
To check if it is working I removed all existing commands and added the command getAussentemperatur which is the first command listed in my vito.xmlfile.
I tried to change the Device ID in the configuration to 204D, which fails vcontrol to start.
So I changed the Device ID back to 2094, which is one of the IDs defined in controls.xml´ This solves the restart issue, but now it doesn't recognize my command getAussentemperatur`.
In the protokol I get:
[77] Sun Nov 19 17:46:23 2023 : Command: getAussentemperatur
[77] Sun Nov 19 17:46:23 2023 : Command: quit
SRV ERR: command unknown
So I thought I change the Device ID in my vito.xml file to 2094 match the ID in the configuration.
But I still get the same error about the unknown command.
What am I missing here?
This is the top most part of my vito.xml (still with the original Device ID):
<vito>
<devices>
<device ID="204D" name="V200-S" protocol="P300"/>
</devices>
<commands>
<!-- TEMPERATUREN -->
<command name="getAussentemperatur" protocmd="getaddr">
<addr>0101</addr>
<len>2</len>
<unit>UT</unit>
<description>Ermittle Aussentemperatur in Grad C (-40..70)</description>
</command>
Seems to work, thanks :-)
Hint for others: the vito.xml needs to be saved in /config/vcontrold (/config being the root of the "file editor").
My list of commands:
- getTempA:FLOAT
- getTempVListM1:FLOAT
- getTempVListM2:FLOAT
- getTempVLsollM1:FLOAT
- getTempRL17A:FLOAT
- getTempSpu:FLOAT
- getUmschaltventil:FLOAT
My yaml:
mqtt: binary_sensor: - name: Status Umschaltventil unique_id: vcontroldgetUmschaltventil state_topic: openv/getUmschaltventil device_class: running value_template: "{% if(value|int == '0') %}OFF{% else %}ON{% endif %}" device: identifiers: vcontrold manufacturer: Viessmann sensor: - name: Aussentemperatur unique_id: vcontroldgetTempA device_class: temperature state_topic: openv/getTempA unit_of_measurement: °C value_template: "{{ value | round(2) }}" device: identifiers: vcontrold manufacturer: Viessmann - name: Vorlauftemperatur M1 unique_id: vcontroldgetTempVListM1 state_topic: openv/getTempVListM1 device: identifiers: vcontrold manufacturer: Viessmann unit_of_measurement: °C value_template: "{{ value | round(2) }}" - name: Vorlauftemperatur M2 unique_id: vcontroldgetTempVListM2 state_topic: openv/getTempVListM2 device: identifiers: vcontrold manufacturer: Viessmann unit_of_measurement: °C value_template: "{{ value | round(2) }}" - name: Vorlaufsolltemperatur M1 unique_id: vcontroldgetTempVLsollM1 state_topic: openv/getTempVLsollM1 device: identifiers: vcontrold manufacturer: Viessmann unit_of_measurement: °C value_template: "{{ value | round(2) }}" - name: Ruecklauftemperatur 17A unique_id: vcontroldgetTempRL17A state_topic: openv/getTempRL17A device: identifiers: vcontrold manufacturer: Viessmann unit_of_measurement: °C value_template: "{{ value | round(2) }}" - name: Speichertemperatur unten unique_id: vcontroldgetTempSpu state_topic: openv/getTempSpu device: identifiers: vcontrold manufacturer: Viessmann unit_of_measurement: °C value_template: "{{ value | round(2) }}"I think that some more commands should be adaptable for the Vitocal 200S, but this is a thing for the next days ;-)
No matter what I try, I don't see any changes in the add-on.
Since you are using file explorer too, what do you mean with /config is the root of the explorer? For some reason any path I can access starts with /files.
I placed it here /files/config/addons_config/vcontrold/vito.xml And here /files/config/vcontrold/vito.xml
The vito.xml has a wrong device id so it definitely throw a error in the log when the add-on starts but there's nothing.
Somebody please help.
I do not use the external vito.xml, but did you try this?
And then use the file upload function for your vito.xml
I do not use the external vito.xml, but did you try this?
And then use the file upload function for your vito.xml
Worked! Thanks
And then use the file upload function for your vito.xml